This is a direct replacement for the Euclid Probe.
This is only replacing the lower PCB, which means it doesnt matter if youre using a 24v or 5v euclid.
A Combination of Euclid Probe and Unklicky.
Bom
Name | Pieces |
---|---|
Stock Euclid Magnets | 2 |
M1.6 x 6MM | 2 |
M2 x 10MM | 2 |
6x3MM Magnet | 1 |
10x5x2MM Magnet | 1 |
Switch is NC.
Works with the Original Euclid Dock without any modifications! (ofc you might need to modify your coords)
it works with auto-z too, i will post offsets etc. soon but you might figure it out by yourselfs for now.
ASSEMBLY INSTRUCTIONS
Push 10x5x2MM Magnet down into Base
Screw Down Euclid Magnets using M1.6X6MM Screws
Screw in M2x10MM halfway, put pin inside and screw in all the way
Enjoy your Magnetic Switch!