diff --git a/idd/Energy+.idd.in b/idd/Energy+.idd.in index cacb39ff897..8ea0c871c0e 100644 --- a/idd/Energy+.idd.in +++ b/idd/Energy+.idd.in @@ -37333,43 +37333,49 @@ ZoneHVAC:HybridUnitaryHVAC, \note Enter the name of the Supply Air Temperature Lookup Table for Mode 10. \note Units for lookup table values should be in C. \note If this field is blank, Mode 10 will not be considered for any time step that requires ventilation, heating, cooling, humidification, or dehumidification. - A111, \field Mode 10 Supply Air Humidity Ratio Lookup Table Name + A111, \field Mode 10 Supply Air Temperature Lookup Table Name + \type object-list + \object-list MultivariateFunctions + \note Enter the name of the Supply Air Temperature Lookup Table for Mode 1. + \note Units for lookup table values should be in C. + \note If this field is blank, Mode 1 will not be considered for any time step that requires ventilation, heating, cooling, humidification, or dehumidification. + A112, \field Mode 10 Supply Air Humidity Ratio Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Supply Air Humidity Ratio Lookup Table for Mode 10. \note Units for lookup table values should be in kgWater/kgDryAir. \note If this field is blank, Mode 10 will not be considered for any time step that requires ventilation, heating, cooling, humidification, or dehumidification. - A112, \field Mode 10 System Electric Power Lookup Table Name + A113, \field Mode 10 System Electric Power Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Electric Power Lookup Table for Mode 10. \note Units for lookup table values should be in W. \note If this field is blank, Mode 10 does not consume electricity. - A113, \field Mode 10 Supply Fan Electric Power Lookup Table Name + A114, \field Mode 10 Supply Fan Electric Power Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Supply Fan Electric Power Lookup Table for Mode 10. \note Units for lookup table values should be in W. \note If this field is blank, Mode 10 will not be considered for any time step that requires ventilation, heating, cooling, humidification, or dehumidification. - A114, \field Mode 10 External Static Pressure Lookup Table Name + A115, \field Mode 10 External Static Pressure Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the External Static Pressure Lookup Table for Mode 10. \note Units for lookup table values should be in Pa. \note If this field is blank, external static pressure will not be reported for Mode 10. - A115, \field Mode 10 System Second Fuel Consumption Lookup Table Name + A116, \field Mode 10 System Second Fuel Consumption Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the System Second Fuel Consumption Lookup Table for Mode 10. \note Units for lookup table values should be in W. \note If this field is blank, Mode 10 does not consume a second fuel. - A116, \field Mode 10 System Third Fuel Consumption Lookup Table Name + A117, \field Mode 10 System Third Fuel Consumption Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the System Third Fuel Consumption Lookup Table for Mode 10. \note Units for lookup table values should be in W. \note If this field is blank, Mode 10 does not consume a third fuel. - A117, \field Mode 10 System Water Use Lookup Table Name + A118, \field Mode 10 System Water Use Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the System Water Use Lookup Table for Mode 10. @@ -37508,53 +37514,53 @@ ZoneHVAC:HybridUnitaryHVAC, \note Supply air mass flow rate ratio describes supply air flow rate as a fraction of the value in field: "System Maximum Supply Air Flow Rate". \note If this field is blank, there upper constraint on supply air mass flow rate ratio will be 1.00. \default 1.00 - A118, \field Mode 11 Name + A119, \field Mode 11 Name \type alpha \retaincase \note Enter a name for Mode 11. - A119, \field Mode 11 Supply Air Temperature Lookup Table Name + A120, \field Mode 11 Supply Air Temperature Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Supply Air Temperature Lookup Table for Mode 11. \note Units for lookup table values should be in C. \note If this field is blank, Mode 11 will not be considered for any time step that requires ventilation, heating, cooling, humidification, or dehumidification. - A120, \field Mode 11 Supply Air Humidity Ratio Lookup Table Name + A121, \field Mode 11 Supply Air Humidity Ratio Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Supply Air Humidity Ratio Lookup Table for Mode 11. \note Units for lookup table values should be in kgWater/kgDryAir. \note If this field is blank, Mode 11 will not be considered for any time step that requires ventilation, heating, cooling, humidification, or dehumidification. - A121, \field Mode 11 System Electric Power Lookup Table Name + A122, \field Mode 11 System Electric Power Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Electric Power Lookup Table for Mode 11. \note Units for lookup table values should be in W. \note If this field is blank, Mode 11 does not consume electricity. - A122, \field Mode 11 Supply Fan Electric Power Lookup Table Name + A123, \field Mode 11 Supply Fan Electric Power Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Supply Fan Electric Power Lookup Table for Mode 11. \note Units for lookup table values should be in W. \note If this field is blank, Mode 11 will not be considered for any time step that requires ventilation, heating, cooling, humidification, or dehumidification. - A123, \field Mode 11 External Static Pressure Lookup Table Name + A124, \field Mode 11 External Static Pressure Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the External Static Pressure Lookup Table for Mode 11. \note Units for lookup table values should be in Pa. \note If this field is blank, external static pressure will not be reported for Mode 11. - A124, \field Mode 11 System Second Fuel Consumption Lookup Table Name + A125, \field Mode 11 System Second Fuel Consumption Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the System Second Fuel Consumption Lookup Table for Mode 11. \note Units for lookup table values should be in W. \note If this field is blank, Mode 11 does not consume a second fuel. - A125, \field Mode 11 System Third Fuel Consumption Lookup Table Name + A126, \field Mode 11 System Third Fuel Consumption Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the System Third Fuel Consumption Lookup Table for Mode 11. \note Units for lookup table values should be in W. \note If this field is blank, Mode 11 does not consume a third fuel. - A126, \field Mode 11 System Water Use Lookup Table Name + A127, \field Mode 11 System Water Use Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the System Water Use Lookup Table for Mode 11. @@ -37693,53 +37699,53 @@ ZoneHVAC:HybridUnitaryHVAC, \note Supply air mass flow rate ratio describes supply air flow rate as a fraction of the value in field: "System Maximum Supply Air Flow Rate". \note If this field is blank, there upper constraint on supply air mass flow rate ratio will be 1.00. \default 1.00 - A127, \field Mode 12 Name + A128, \field Mode 12 Name \type alpha \retaincase \note Enter a name for Mode 12. - A128, \field Mode 12 Supply Air Temperature Lookup Table Name + A129, \field Mode 12 Supply Air Temperature Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Supply Air Temperature Lookup Table for Mode 12. \note Units for lookup table values should be in C. \note If this field is blank, Mode 12 will not be considered for any time step that requires ventilation, heating, cooling, humidification, or dehumidification. - A129, \field Mode 12 Supply Air Humidity Ratio Lookup Table Name + A130, \field Mode 12 Supply Air Humidity Ratio Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Supply Air Humidity Ratio Lookup Table for Mode 12. \note Units for lookup table values should be in kgWater/kgDryAir. \note If this field is blank, Mode 12 will not be considered for any time step that requires ventilation, heating, cooling, humidification, or dehumidification. - A130, \field Mode 12 System Electric Power Lookup Table Name + A131, \field Mode 12 System Electric Power Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Electric Power Lookup Table for Mode 12. \note Units for lookup table values should be in W. \note If this field is blank, Mode 12 does not consume electricity. - A131, \field Mode 12 Supply Fan Electric Power Lookup Table Name + A132, \field Mode 12 Supply Fan Electric Power Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Supply Fan Electric Power Lookup Table for Mode 12. \note Units for lookup table values should be in W. \note If this field is blank, Mode 12 will not be considered for any time step that requires ventilation, heating, cooling, humidification, or dehumidification. - A132, \field Mode 12 External Static Pressure Lookup Table Name + A133, \field Mode 12 External Static Pressure Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the External Static Pressure Lookup Table for Mode 12. \note Units for lookup table values should be in Pa. \note If this field is blank, external static pressure will not be reported for Mode 12. - A133, \field Mode 12 System Second Fuel Consumption Lookup Table Name + A134, \field Mode 12 System Second Fuel Consumption Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the System Second Fuel Consumption Lookup Table for Mode 12. \note Units for lookup table values should be in W. \note If this field is blank, Mode 12 does not consume a second fuel. - A134, \field Mode 12 System Third Fuel Consumption Lookup Table Name + A135, \field Mode 12 System Third Fuel Consumption Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the System Third Fuel Consumption Lookup Table for Mode 12. \note Units for lookup table values should be in W. \note If this field is blank, Mode 12 does not consume a third fuel. - A135, \field Mode 12 System Water Use Lookup Table Name + A136, \field Mode 12 System Water Use Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the System Water Use Lookup Table for Mode 12. @@ -37878,53 +37884,53 @@ ZoneHVAC:HybridUnitaryHVAC, \note Supply air mass flow rate ratio describes supply air flow rate as a fraction of the value in field: "System Maximum Supply Air Flow Rate". \note If this field is blank, there upper constraint on supply air mass flow rate ratio will be 1.00. \default 1.00 - A136, \field Mode 13 Name + A137, \field Mode 13 Name \type alpha \retaincase \note Enter a name for Mode 13. - A137, \field Mode 13 Supply Air Temperature Lookup Table Name + A138, \field Mode 13 Supply Air Temperature Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Supply Air Temperature Lookup Table for Mode 13. \note Units for lookup table values should be in C. \note If this field is blank, Mode 13 will not be considered for any time step that requires ventilation, heating, cooling, humidification, or dehumidification. - A138, \field Mode 13 Supply Air Humidity Ratio Lookup Table Name + A139, \field Mode 13 Supply Air Humidity Ratio Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Supply Air Humidity Ratio Lookup Table for Mode 13. \note Units for lookup table values should be in kgWater/kgDryAir. \note If this field is blank, Mode 13 will not be considered for any time step that requires ventilation, heating, cooling, humidification, or dehumidification. - A139, \field Mode 13 System Electric Power Lookup Table Name + A140, \field Mode 13 System Electric Power Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Electric Power Lookup Table for Mode 13. \note Units for lookup table values should be in W. \note If this field is blank, Mode 13 does not consume electricity. - A140, \field Mode 13 Supply Fan Electric Power Lookup Table Name + A141, \field Mode 13 Supply Fan Electric Power Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Supply Fan Electric Power Lookup Table for Mode 13. \note Units for lookup table values should be in W. \note If this field is blank, Mode 13 will not be considered for any time step that requires ventilation, heating, cooling, humidification, or dehumidification. - A141, \field Mode 13 External Static Pressure Lookup Table Name + A142, \field Mode 13 External Static Pressure Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the External Static Pressure Lookup Table for Mode 13. \note Units for lookup table values should be in Pa. \note If this field is blank, external static pressure will not be reported for Mode 13. - A142, \field Mode 13 System Second Fuel Consumption Lookup Table Name + A143, \field Mode 13 System Second Fuel Consumption Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the System Second Fuel Consumption Lookup Table for Mode 13. \note Units for lookup table values should be in W. \note If this field is blank, Mode 13 does not consume a second fuel. - A143, \field Mode 13 System Third Fuel Consumption Lookup Table Name + A144, \field Mode 13 System Third Fuel Consumption Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the System Third Fuel Consumption Lookup Table for Mode 13. \note Units for lookup table values should be in W. \note If this field is blank, Mode 13 does not consume a third fuel. - A144, \field Mode 13 System Water Use Lookup Table Name + A145, \field Mode 13 System Water Use Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the System Water Use Lookup Table for Mode 13. @@ -38063,53 +38069,53 @@ ZoneHVAC:HybridUnitaryHVAC, \note Supply air mass flow rate ratio describes supply air flow rate as a fraction of the value in field: "System Maximum Supply Air Flow Rate". \note If this field is blank, there upper constraint on supply air mass flow rate ratio will be 1.00. \default 1.00 - A145, \field Mode 14 Name + A146, \field Mode 14 Name \type alpha \retaincase \note Enter a name for Mode 14. - A146, \field Mode 14 Supply Air Temperature Lookup Table Name + A147, \field Mode 14 Supply Air Temperature Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Supply Air Temperature Lookup Table for Mode 14. \note Units for lookup table values should be in C. \note If this field is blank, Mode 14 will not be considered for any time step that requires ventilation, heating, cooling, humidification, or dehumidification. - A147, \field Mode 14 Supply Air Humidity Ratio Lookup Table Name + A148, \field Mode 14 Supply Air Humidity Ratio Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Supply Air Humidity Ratio Lookup Table for Mode 14. \note Units for lookup table values should be in kgWater/kgDryAir. \note If this field is blank, Mode 14 will not be considered for any time step that requires ventilation, heating, cooling, humidification, or dehumidification. - A148, \field Mode 14 System Electric Power Lookup Table Name + A149, \field Mode 14 System Electric Power Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Electric Power Lookup Table for Mode 14. \note Units for lookup table values should be in W. \note If this field is blank, Mode 14 does not consume electricity. - A149, \field Mode 14 Supply Fan Electric Power Lookup Table Name + A150, \field Mode 14 Supply Fan Electric Power Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Supply Fan Electric Power Lookup Table for Mode 14. \note Units for lookup table values should be in W. \note If this field is blank, Mode 14 will not be considered for any time step that requires ventilation, heating, cooling, humidification, or dehumidification. - A150, \field Mode 14 External Static Pressure Lookup Table Name + A151, \field Mode 14 External Static Pressure Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the External Static Pressure Lookup Table for Mode 14. \note Units for lookup table values should be in Pa. \note If this field is blank, external static pressure will not be reported for Mode 14. - A151, \field Mode 14 System Second Fuel Consumption Lookup Table Name + A152, \field Mode 14 System Second Fuel Consumption Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the System Second Fuel Consumption Lookup Table for Mode 14. \note Units for lookup table values should be in W. \note If this field is blank, Mode 14 does not consume a second fuel. - A152, \field Mode 14 System Third Fuel Consumption Lookup Table Name + A153, \field Mode 14 System Third Fuel Consumption Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the System Third Fuel Consumption Lookup Table for Mode 14. \note Units for lookup table values should be in W. \note If this field is blank, Mode 14 does not consume a third fuel. - A153, \field Mode 14 System Water Use Lookup Table Name + A154, \field Mode 14 System Water Use Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the System Water Use Lookup Table for Mode 14. @@ -38248,53 +38254,53 @@ ZoneHVAC:HybridUnitaryHVAC, \note Supply air mass flow rate ratio describes supply air flow rate as a fraction of the value in field: "System Maximum Supply Air Flow Rate". \note If this field is blank, there upper constraint on supply air mass flow rate ratio will be 1.00. \default 1.00 - A154, \field Mode 15 Name + A155, \field Mode 15 Name \type alpha \retaincase \note Enter a name for Mode 15. - A155, \field Mode 15 Supply Air Temperature Lookup Table Name + A156, \field Mode 15 Supply Air Temperature Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Supply Air Temperature Lookup Table for Mode 15. \note Units for lookup table values should be in C. \note If this field is blank, Mode 15 will not be considered for any time step that requires ventilation, heating, cooling, humidification, or dehumidification. - A156, \field Mode 15 Supply Air Humidity Ratio Lookup Table Name + A157, \field Mode 15 Supply Air Humidity Ratio Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Supply Air Humidity Ratio Lookup Table for Mode 15. \note Units for lookup table values should be in kgWater/kgDryAir. \note If this field is blank, Mode 15 will not be considered for any time step that requires ventilation, heating, cooling, humidification, or dehumidification. - A157, \field Mode 15 System Electric Power Lookup Table Name + A158, \field Mode 15 System Electric Power Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Electric Power Lookup Table for Mode 15. \note Units for lookup table values should be in W. \note If this field is blank, Mode 15 does not consume electricity. - A158, \field Mode 15 Supply Fan Electric Power Lookup Table Name + A159, \field Mode 15 Supply Fan Electric Power Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Supply Fan Electric Power Lookup Table for Mode 15. \note Units for lookup table values should be in W. \note If this field is blank, Mode 15 will not be considered for any time step that requires ventilation, heating, cooling, humidification, or dehumidification. - A159, \field Mode 15 External Static Pressure Lookup Table Name + A160, \field Mode 15 External Static Pressure Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the External Static Pressure Lookup Table for Mode 15. \note Units for lookup table values should be in Pa. \note If this field is blank, external static pressure will not be reported for Mode 15. - A160, \field Mode 15 System Second Fuel Consumption Lookup Table Name + A161, \field Mode 15 System Second Fuel Consumption Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the System Second Fuel Consumption Lookup Table for Mode 15. \note Units for lookup table values should be in W. \note If this field is blank, Mode 15 does not consume a second fuel. - A161, \field Mode 15 System Third Fuel Consumption Lookup Table Name + A162, \field Mode 15 System Third Fuel Consumption Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the System Third Fuel Consumption Lookup Table for Mode 15. \note Units for lookup table values should be in W. \note If this field is blank, Mode 15 does not consume a third fuel. - A162, \field Mode 15 System Water Use Lookup Table Name + A163, \field Mode 15 System Water Use Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the System Water Use Lookup Table for Mode 15. @@ -38433,53 +38439,53 @@ ZoneHVAC:HybridUnitaryHVAC, \note Supply air mass flow rate ratio describes supply air flow rate as a fraction of the value in field: "System Maximum Supply Air Flow Rate". \note If this field is blank, there upper constraint on supply air mass flow rate ratio will be 1.00. \default 1.00 - A163, \field Mode 16 Name + A164, \field Mode 16 Name \type alpha \retaincase \note Enter a name for Mode 16. - A164, \field Mode 16 Supply Air Temperature Lookup Table Name + A165, \field Mode 16 Supply Air Temperature Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Supply Air Temperature Lookup Table for Mode 16. \note Units for lookup table values should be in C. \note If this field is blank, Mode 16 will not be considered for any time step that requires ventilation, heating, cooling, humidification, or dehumidification. - A165, \field Mode 16 Supply Air Humidity Ratio Lookup Table Name + A166, \field Mode 16 Supply Air Humidity Ratio Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Supply Air Humidity Ratio Lookup Table for Mode 16. \note Units for lookup table values should be in kgWater/kgDryAir. \note If this field is blank, Mode 16 will not be considered for any time step that requires ventilation, heating, cooling, humidification, or dehumidification. - A166, \field Mode 16 System Electric Power Lookup Table Name + A167, \field Mode 16 System Electric Power Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Electric Power Lookup Table for Mode 16. \note Units for lookup table values should be in W. \note If this field is blank, Mode 16 does not consume electricity. - A167, \field Mode 16 Supply Fan Electric Power Lookup Table Name + A168, \field Mode 16 Supply Fan Electric Power Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Supply Fan Electric Power Lookup Table for Mode 16. \note Units for lookup table values should be in W. \note If this field is blank, Mode 16 will not be considered for any time step that requires ventilation, heating, cooling, humidification, or dehumidification. - A168, \field Mode 16 External Static Pressure Lookup Table Name + A169, \field Mode 16 External Static Pressure Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the External Static Pressure Lookup Table for Mode 16. \note Units for lookup table values should be in Pa. \note If this field is blank, external static pressure will not be reported for Mode 16. - A169, \field Mode 16 System Second Fuel Consumption Lookup Table Name + A170, \field Mode 16 System Second Fuel Consumption Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the System Second Fuel Consumption Lookup Table for Mode 16. \note Units for lookup table values should be in W. \note If this field is blank, Mode 16 does not consume a second fuel. - A170, \field Mode 16 System Third Fuel Consumption Lookup Table Name + A171, \field Mode 16 System Third Fuel Consumption Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the System Third Fuel Consumption Lookup Table for Mode 16. \note Units for lookup table values should be in W. \note If this field is blank, Mode 16 does not consume a third fuel. - A171, \field Mode 16 System Water Use Lookup Table Name + A172, \field Mode 16 System Water Use Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the System Water Use Lookup Table for Mode 16. @@ -38618,53 +38624,53 @@ ZoneHVAC:HybridUnitaryHVAC, \note Supply air mass flow rate ratio describes supply air flow rate as a fraction of the value in field: "System Maximum Supply Air Flow Rate". \note If this field is blank, there upper constraint on supply air mass flow rate ratio will be 1.00. \default 1.00 - A172, \field Mode 17 Name + A173, \field Mode 17 Name \type alpha \retaincase \note Enter a name for Mode 17. - A173, \field Mode 17 Supply Air Temperature Lookup Table Name + A174, \field Mode 17 Supply Air Temperature Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Supply Air Temperature Lookup Table for Mode 17. \note Units for lookup table values should be in C. \note If this field is blank, Mode 17 will not be considered for any time step that requires ventilation, heating, cooling, humidification, or dehumidification. - A174, \field Mode 17 Supply Air Humidity Ratio Lookup Table Name + A175, \field Mode 17 Supply Air Humidity Ratio Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Supply Air Humidity Ratio Lookup Table for Mode 17. \note Units for lookup table values should be in kgWater/kgDryAir. \note If this field is blank, Mode 17 will not be considered for any time step that requires ventilation, heating, cooling, humidification, or dehumidification. - A175, \field Mode 17 System Electric Power Lookup Table Name + A176, \field Mode 17 System Electric Power Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Electric Power Lookup Table for Mode 17. \note Units for lookup table values should be in W. \note If this field is blank, Mode 17 does not consume electricity. - A176, \field Mode 17 Supply Fan Electric Power Lookup Table Name + A177, \field Mode 17 Supply Fan Electric Power Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Supply Fan Electric Power Lookup Table for Mode 17. \note Units for lookup table values should be in W. \note If this field is blank, Mode 17 will not be considered for any time step that requires ventilation, heating, cooling, humidification, or dehumidification. - A177, \field Mode 17 External Static Pressure Lookup Table Name + A178, \field Mode 17 External Static Pressure Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the External Static Pressure Lookup Table for Mode 17. \note Units for lookup table values should be in Pa. \note If this field is blank, external static pressure will not be reported for Mode 17. - A178, \field Mode 17 System Second Fuel Consumption Lookup Table Name + A179, \field Mode 17 System Second Fuel Consumption Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the System Second Fuel Consumption Lookup Table for Mode 17. \note Units for lookup table values should be in W. \note If this field is blank, Mode 17 does not consume a second fuel. - A179, \field Mode 17 System Third Fuel Consumption Lookup Table Name + A180, \field Mode 17 System Third Fuel Consumption Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the System Third Fuel Consumption Lookup Table for Mode 17. \note Units for lookup table values should be in W. \note If this field is blank, Mode 17 does not consume a third fuel. - A180, \field Mode 17 System Water Use Lookup Table Name + A181, \field Mode 17 System Water Use Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the System Water Use Lookup Table for Mode 17. @@ -38803,53 +38809,53 @@ ZoneHVAC:HybridUnitaryHVAC, \note Supply air mass flow rate ratio describes supply air flow rate as a fraction of the value in field: "System Maximum Supply Air Flow Rate". \note If this field is blank, there upper constraint on supply air mass flow rate ratio will be 1.00. \default 1.00 - A181, \field Mode 18 Name + A182, \field Mode 18 Name \type alpha \retaincase \note Enter a name for Mode 18. - A182, \field Mode 18 Supply Air Temperature Lookup Table Name + A183, \field Mode 18 Supply Air Temperature Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Supply Air Temperature Lookup Table for Mode 18. \note Units for lookup table values should be in C. \note If this field is blank, Mode 18 will not be considered for any time step that requires ventilation, heating, cooling, humidification, or dehumidification. - A183, \field Mode 18 Supply Air Humidity Ratio Lookup Table Name + A184, \field Mode 18 Supply Air Humidity Ratio Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Supply Air Humidity Ratio Lookup Table for Mode 18. \note Units for lookup table values should be in kgWater/kgDryAir. \note If this field is blank, Mode 18 will not be considered for any time step that requires ventilation, heating, cooling, humidification, or dehumidification. - A184, \field Mode 18 System Electric Power Lookup Table Name + A185, \field Mode 18 System Electric Power Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Electric Power Lookup Table for Mode 18. \note Units for lookup table values should be in W. \note If this field is blank, Mode 18 does not consume electricity. - A185, \field Mode 18 Supply Fan Electric Power Lookup Table Name + A186, \field Mode 18 Supply Fan Electric Power Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Supply Fan Electric Power Lookup Table for Mode 18. \note Units for lookup table values should be in W. \note If this field is blank, Mode 18 will not be considered for any time step that requires ventilation, heating, cooling, humidification, or dehumidification. - A186, \field Mode 18 External Static Pressure Lookup Table Name + A187, \field Mode 18 External Static Pressure Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the External Static Pressure Lookup Table for Mode 18. \note Units for lookup table values should be in Pa. \note If this field is blank, external static pressure will not be reported for Mode 18. - A187, \field Mode 18 System Second Fuel Consumption Lookup Table Name + A188, \field Mode 18 System Second Fuel Consumption Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the System Second Fuel Consumption Lookup Table for Mode 18. \note Units for lookup table values should be in W. \note If this field is blank, Mode 18 does not consume a second fuel. - A188, \field Mode 18 System Third Fuel Consumption Lookup Table Name + A189, \field Mode 18 System Third Fuel Consumption Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the System Third Fuel Consumption Lookup Table for Mode 18. \note Units for lookup table values should be in W. \note If this field is blank, Mode 18 does not consume a third fuel. - A189, \field Mode 18 System Water Use Lookup Table Name + A190, \field Mode 18 System Water Use Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the System Water Use Lookup Table for Mode 18. @@ -38988,53 +38994,53 @@ ZoneHVAC:HybridUnitaryHVAC, \note Supply air mass flow rate ratio describes supply air flow rate as a fraction of the value in field: "System Maximum Supply Air Flow Rate". \note If this field is blank, there upper constraint on supply air mass flow rate ratio will be 1.00. \default 1.00 - A190, \field Mode 19 Name + A191, \field Mode 19 Name \type alpha \retaincase \note Enter a name for Mode 19. - A191, \field Mode 19 Supply Air Temperature Lookup Table Name + A192, \field Mode 19 Supply Air Temperature Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Supply Air Temperature Lookup Table for Mode 19. \note Units for lookup table values should be in C. \note If this field is blank, Mode 19 will not be considered for any time step that requires ventilation, heating, cooling, humidification, or dehumidification. - A192, \field Mode 19 Supply Air Humidity Ratio Lookup Table Name + A193, \field Mode 19 Supply Air Humidity Ratio Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Supply Air Humidity Ratio Lookup Table for Mode 19. \note Units for lookup table values should be in kgWater/kgDryAir. \note If this field is blank, Mode 19 will not be considered for any time step that requires ventilation, heating, cooling, humidification, or dehumidification. - A193, \field Mode 19 System Electric Power Lookup Table Name + A194, \field Mode 19 System Electric Power Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Electric Power Lookup Table for Mode 19. \note Units for lookup table values should be in W. \note If this field is blank, Mode 19 does not consume electricity. - A194, \field Mode 19 Supply Fan Electric Power Lookup Table Name + A195, \field Mode 19 Supply Fan Electric Power Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Supply Fan Electric Power Lookup Table for Mode 19. \note Units for lookup table values should be in W. \note If this field is blank, Mode 19 will not be considered for any time step that requires ventilation, heating, cooling, humidification, or dehumidification. - A195, \field Mode 19 External Static Pressure Lookup Table Name + A196, \field Mode 19 External Static Pressure Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the External Static Pressure Lookup Table for Mode 19. \note Units for lookup table values should be in Pa. \note If this field is blank, external static pressure will not be reported for Mode 19. - A196, \field Mode 19 System Second Fuel Consumption Lookup Table Name + A197, \field Mode 19 System Second Fuel Consumption Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the System Second Fuel Consumption Lookup Table for Mode 19. \note Units for lookup table values should be in W. \note If this field is blank, Mode 19 does not consume a second fuel. - A197, \field Mode 19 System Third Fuel Consumption Lookup Table Name + A198, \field Mode 19 System Third Fuel Consumption Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the System Third Fuel Consumption Lookup Table for Mode 19. \note Units for lookup table values should be in W. \note If this field is blank, Mode 19 does not consume a third fuel. - A198, \field Mode 19 System Water Use Lookup Table Name + A199, \field Mode 19 System Water Use Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the System Water Use Lookup Table for Mode 19. @@ -39173,53 +39179,53 @@ ZoneHVAC:HybridUnitaryHVAC, \note Supply air mass flow rate ratio describes supply air flow rate as a fraction of the value in field: "System Maximum Supply Air Flow Rate". \note If this field is blank, there upper constraint on supply air mass flow rate ratio will be 1.00. \default 1.00 - A199, \field Mode 20 Name + A200, \field Mode 20 Name \type alpha \retaincase \note Enter a name for Mode 20. - A200, \field Mode 20 Supply Air Temperature Lookup Table Name + A201, \field Mode 20 Supply Air Temperature Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Supply Air Temperature Lookup Table for Mode 20. \note Units for lookup table values should be in C. \note If this field is blank, Mode 20 will not be considered for any time step that requires ventilation, heating, cooling, humidification, or dehumidification. - A201, \field Mode 20 Supply Air Humidity Ratio Lookup Table Name + A202, \field Mode 20 Supply Air Humidity Ratio Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Supply Air Humidity Ratio Lookup Table for Mode 20. \note Units for lookup table values should be in kgWater/kgDryAir. \note If this field is blank, Mode 20 will not be considered for any time step that requires ventilation, heating, cooling, humidification, or dehumidification. - A202, \field Mode 20 System Electric Power Lookup Table Name + A203, \field Mode 20 System Electric Power Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Electric Power Lookup Table for Mode 20. \note Units for lookup table values should be in W. \note If this field is blank, Mode 20 does not consume electricity. - A203, \field Mode 20 Supply Fan Electric Power Lookup Table Name + A204, \field Mode 20 Supply Fan Electric Power Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Supply Fan Electric Power Lookup Table for Mode 20. \note Units for lookup table values should be in W. \note If this field is blank, Mode 20 will not be considered for any time step that requires ventilation, heating, cooling, humidification, or dehumidification. - A204, \field Mode 20 External Static Pressure Lookup Table Name + A205, \field Mode 20 External Static Pressure Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the External Static Pressure Lookup Table for Mode 20. \note Units for lookup table values should be in Pa. \note If this field is blank, external static pressure will not be reported for Mode 20. - A205, \field Mode 20 System Second Fuel Consumption Lookup Table Name + A206, \field Mode 20 System Second Fuel Consumption Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the System Second Fuel Consumption Lookup Table for Mode 20. \note Units for lookup table values should be in W. \note If this field is blank, Mode 20 does not consume a second fuel. - A206, \field Mode 20 System Third Fuel Consumption Lookup Table Name + A207, \field Mode 20 System Third Fuel Consumption Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the System Third Fuel Consumption Lookup Table for Mode 20. \note Units for lookup table values should be in W. \note If this field is blank, Mode 20 does not consume a third fuel. - A207, \field Mode 20 System Water Use Lookup Table Name + A208, \field Mode 20 System Water Use Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the System Water Use Lookup Table for Mode 20. @@ -39358,53 +39364,53 @@ ZoneHVAC:HybridUnitaryHVAC, \note Supply air mass flow rate ratio describes supply air flow rate as a fraction of the value in field: "System Maximum Supply Air Flow Rate". \note If this field is blank, there upper constraint on supply air mass flow rate ratio will be 1.00. \default 1.00 - A208, \field Mode 21 Name + A209, \field Mode 21 Name \type alpha \retaincase \note Enter a name for Mode 21. - A209, \field Mode 21 Supply Air Temperature Lookup Table Name + A210, \field Mode 21 Supply Air Temperature Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Supply Air Temperature Lookup Table for Mode 21. \note Units for lookup table values should be in C. \note If this field is blank, Mode 21 will not be considered for any time step that requires ventilation, heating, cooling, humidification, or dehumidification. - A210, \field Mode 21 Supply Air Humidity Ratio Lookup Table Name + A211, \field Mode 21 Supply Air Humidity Ratio Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Supply Air Humidity Ratio Lookup Table for Mode 21. \note Units for lookup table values should be in kgWater/kgDryAir. \note If this field is blank, Mode 21 will not be considered for any time step that requires ventilation, heating, cooling, humidification, or dehumidification. - A211, \field Mode 21 System Electric Power Lookup Table Name + A212, \field Mode 21 System Electric Power Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Electric Power Lookup Table for Mode 21. \note Units for lookup table values should be in W. \note If this field is blank, Mode 21 does not consume electricity. - A212, \field Mode 21 Supply Fan Electric Power Lookup Table Name + A213, \field Mode 21 Supply Fan Electric Power Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Supply Fan Electric Power Lookup Table for Mode 21. \note Units for lookup table values should be in W. \note If this field is blank, Mode 21 will not be considered for any time step that requires ventilation, heating, cooling, humidification, or dehumidification. - A213, \field Mode 21 External Static Pressure Lookup Table Name + A214, \field Mode 21 External Static Pressure Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the External Static Pressure Lookup Table for Mode 21. \note Units for lookup table values should be in Pa. \note If this field is blank, external static pressure will not be reported for Mode 21. - A214, \field Mode 21 System Second Fuel Consumption Lookup Table Name + A215, \field Mode 21 System Second Fuel Consumption Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the System Second Fuel Consumption Lookup Table for Mode 21. \note Units for lookup table values should be in W. \note If this field is blank, Mode 21 does not consume a second fuel. - A215, \field Mode 21 System Third Fuel Consumption Lookup Table Name + A216, \field Mode 21 System Third Fuel Consumption Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the System Third Fuel Consumption Lookup Table for Mode 21. \note Units for lookup table values should be in W. \note If this field is blank, Mode 21 does not consume a third fuel. - A216, \field Mode 21 System Water Use Lookup Table Name + A217, \field Mode 21 System Water Use Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the System Water Use Lookup Table for Mode 21. @@ -39543,53 +39549,53 @@ ZoneHVAC:HybridUnitaryHVAC, \note Supply air mass flow rate ratio describes supply air flow rate as a fraction of the value in field: "System Maximum Supply Air Flow Rate". \note If this field is blank, there upper constraint on supply air mass flow rate ratio will be 1.00. \default 1.00 - A217, \field Mode 22 Name + A218, \field Mode 22 Name \type alpha \retaincase \note Enter a name for Mode 22. - A218, \field Mode 22 Supply Air Temperature Lookup Table Name + A219, \field Mode 22 Supply Air Temperature Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Supply Air Temperature Lookup Table for Mode 22. \note Units for lookup table values should be in C. \note If this field is blank, Mode 22 will not be considered for any time step that requires ventilation, heating, cooling, humidification, or dehumidification. - A219, \field Mode 22 Supply Air Humidity Ratio Lookup Table Name + A220, \field Mode 22 Supply Air Humidity Ratio Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Supply Air Humidity Ratio Lookup Table for Mode 22. \note Units for lookup table values should be in kgWater/kgDryAir. \note If this field is blank, Mode 22 will not be considered for any time step that requires ventilation, heating, cooling, humidification, or dehumidification. - A220, \field Mode 22 System Electric Power Lookup Table Name + A221, \field Mode 22 System Electric Power Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Electric Power Lookup Table for Mode 22. \note Units for lookup table values should be in W. \note If this field is blank, Mode 22 does not consume electricity. - A221, \field Mode 22 Supply Fan Electric Power Lookup Table Name + A222, \field Mode 22 Supply Fan Electric Power Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Supply Fan Electric Power Lookup Table for Mode 22. \note Units for lookup table values should be in W. \note If this field is blank, Mode 22 will not be considered for any time step that requires ventilation, heating, cooling, humidification, or dehumidification. - A222, \field Mode 22 External Static Pressure Lookup Table Name + A223, \field Mode 22 External Static Pressure Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the External Static Pressure Lookup Table for Mode 22. \note Units for lookup table values should be in Pa. \note If this field is blank, external static pressure will not be reported for Mode 22. - A223, \field Mode 22 System Second Fuel Consumption Lookup Table Name + A224, \field Mode 22 System Second Fuel Consumption Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the System Second Fuel Consumption Lookup Table for Mode 22. \note Units for lookup table values should be in W. \note If this field is blank, Mode 22 does not consume a second fuel. - A224, \field Mode 22 System Third Fuel Consumption Lookup Table Name + A225, \field Mode 22 System Third Fuel Consumption Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the System Third Fuel Consumption Lookup Table for Mode 22. \note Units for lookup table values should be in W. \note If this field is blank, Mode 22 does not consume a third fuel. - A225, \field Mode 22 System Water Use Lookup Table Name + A226, \field Mode 22 System Water Use Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the System Water Use Lookup Table for Mode 22. @@ -39728,53 +39734,53 @@ ZoneHVAC:HybridUnitaryHVAC, \note Supply air mass flow rate ratio describes supply air flow rate as a fraction of the value in field: "System Maximum Supply Air Flow Rate". \note If this field is blank, there upper constraint on supply air mass flow rate ratio will be 1.00. \default 1.00 - A226, \field Mode 23 Name + A227, \field Mode 23 Name \type alpha \retaincase \note Enter a name for Mode 23. - A227, \field Mode 23 Supply Air Temperature Lookup Table Name + A228, \field Mode 23 Supply Air Temperature Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Supply Air Temperature Lookup Table for Mode 23. \note Units for lookup table values should be in C. \note If this field is blank, Mode 23 will not be considered for any time step that requires ventilation, heating, cooling, humidification, or dehumidification. - A228, \field Mode 23 Supply Air Humidity Ratio Lookup Table Name + A229, \field Mode 23 Supply Air Humidity Ratio Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Supply Air Humidity Ratio Lookup Table for Mode 23. \note Units for lookup table values should be in kgWater/kgDryAir. \note If this field is blank, Mode 23 will not be considered for any time step that requires ventilation, heating, cooling, humidification, or dehumidification. - A229, \field Mode 23 System Electric Power Lookup Table Name + A230, \field Mode 23 System Electric Power Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Electric Power Lookup Table for Mode 23. \note Units for lookup table values should be in W. \note If this field is blank, Mode 23 does not consume electricity. - A230, \field Mode 23 Supply Fan Electric Power Lookup Table Name + A231, \field Mode 23 Supply Fan Electric Power Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Supply Fan Electric Power Lookup Table for Mode 23. \note Units for lookup table values should be in W. \note If this field is blank, Mode 23 will not be considered for any time step that requires ventilation, heating, cooling, humidification, or dehumidification. - A231, \field Mode 23 External Static Pressure Lookup Table Name + A232, \field Mode 23 External Static Pressure Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the External Static Pressure Lookup Table for Mode 23. \note Units for lookup table values should be in Pa. \note If this field is blank, external static pressure will not be reported for Mode 23. - A232, \field Mode 23 System Second Fuel Consumption Lookup Table Name + A233, \field Mode 23 System Second Fuel Consumption Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the System Second Fuel Consumption Lookup Table for Mode 23. \note Units for lookup table values should be in W. \note If this field is blank, Mode 23 does not consume a second fuel. - A233, \field Mode 23 System Third Fuel Consumption Lookup Table Name + A234, \field Mode 23 System Third Fuel Consumption Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the System Third Fuel Consumption Lookup Table for Mode 23. \note Units for lookup table values should be in W. \note If this field is blank, Mode 23 does not consume a third fuel. - A234, \field Mode 23 System Water Use Lookup Table Name + A235, \field Mode 23 System Water Use Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the System Water Use Lookup Table for Mode 23. @@ -39913,53 +39919,53 @@ ZoneHVAC:HybridUnitaryHVAC, \note Supply air mass flow rate ratio describes supply air flow rate as a fraction of the value in field: "System Maximum Supply Air Flow Rate". \note If this field is blank, there upper constraint on supply air mass flow rate ratio will be 1.00. \default 1.00 - A235, \field Mode 24 Name + A236, \field Mode 24 Name \type alpha \retaincase \note Enter a name for Mode 24. - A236, \field Mode 24 Supply Air Temperature Lookup Table Name + A237, \field Mode 24 Supply Air Temperature Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Supply Air Temperature Lookup Table for Mode 24. \note Units for lookup table values should be in C. \note If this field is blank, Mode 24 will not be considered for any time step that requires ventilation, heating, cooling, humidification, or dehumidification. - A237, \field Mode 24 Supply Air Humidity Ratio Lookup Table Name + A238, \field Mode 24 Supply Air Humidity Ratio Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Supply Air Humidity Ratio Lookup Table for Mode 24. \note Units for lookup table values should be in kgWater/kgDryAir. \note If this field is blank, Mode 24 will not be considered for any time step that requires ventilation, heating, cooling, humidification, or dehumidification. - A238, \field Mode 24 System Electric Power Lookup Table Name + A239, \field Mode 24 System Electric Power Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Electric Power Lookup Table for Mode 24. \note Units for lookup table values should be in W. \note If this field is blank, Mode 24 does not consume electricity. - A239, \field Mode 24 Supply Fan Electric Power Lookup Table Name + A240, \field Mode 24 Supply Fan Electric Power Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Supply Fan Electric Power Lookup Table for Mode 24. \note Units for lookup table values should be in W. \note If this field is blank, Mode 24 will not be considered for any time step that requires ventilation, heating, cooling, humidification, or dehumidification. - A240, \field Mode 24 External Static Pressure Lookup Table Name + A241, \field Mode 24 External Static Pressure Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the External Static Pressure Lookup Table for Mode 24. \note Units for lookup table values should be in Pa. \note If this field is blank, external static pressure will not be reported for Mode 24. - A241, \field Mode 24 System Second Fuel Consumption Lookup Table Name + A242, \field Mode 24 System Second Fuel Consumption Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the System Second Fuel Consumption Lookup Table for Mode 24. \note Units for lookup table values should be in W. \note If this field is blank, Mode 24 does not consume a second fuel. - A242, \field Mode 24 System Third Fuel Consumption Lookup Table Name + A243, \field Mode 24 System Third Fuel Consumption Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the System Third Fuel Consumption Lookup Table for Mode 24. \note Units for lookup table values should be in W. \note If this field is blank, Mode 24 does not consume a third fuel. - A243, \field Mode 24 System Water Use Lookup Table Name + A244, \field Mode 24 System Water Use Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the System Water Use Lookup Table for Mode 24. @@ -40098,53 +40104,53 @@ ZoneHVAC:HybridUnitaryHVAC, \note Supply air mass flow rate ratio describes supply air flow rate as a fraction of the value in field: "System Maximum Supply Air Flow Rate". \note If this field is blank, there upper constraint on supply air mass flow rate ratio will be 1.00. \default 1.00 - A244, \field Mode 25 Name + A245, \field Mode 25 Name \type alpha \retaincase \note Enter a name for Mode 25. - A245, \field Mode 25 Supply Air Temperature Lookup Table Name + A246, \field Mode 25 Supply Air Temperature Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Supply Air Temperature Lookup Table for Mode 25. \note Units for lookup table values should be in C. \note If this field is blank, Mode 25 will not be considered for any time step that requires ventilation, heating, cooling, humidification, or dehumidification. - A246, \field Mode 25 Supply Air Humidity Ratio Lookup Table Name + A247, \field Mode 25 Supply Air Humidity Ratio Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Supply Air Humidity Ratio Lookup Table for Mode 25. \note Units for lookup table values should be in kgWater/kgDryAir. \note If this field is blank, Mode 25 will not be considered for any time step that requires ventilation, heating, cooling, humidification, or dehumidification. - A247, \field Mode 25 System Electric Power Lookup Table Name + A248, \field Mode 25 System Electric Power Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Electric Power Lookup Table for Mode 25. \note Units for lookup table values should be in W. \note If this field is blank, Mode 25 does not consume electricity. - A248, \field Mode 25 Supply Fan Electric Power Lookup Table Name + A249, \field Mode 25 Supply Fan Electric Power Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the Supply Fan Electric Power Lookup Table for Mode 25. \note Units for lookup table values should be in W. \note If this field is blank, Mode 25 will not be considered for any time step that requires ventilation, heating, cooling, humidification, or dehumidification. - A249, \field Mode 25 External Static Pressure Lookup Table Name + A250, \field Mode 25 External Static Pressure Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the External Static Pressure Lookup Table for Mode 25. \note Units for lookup table values should be in Pa. \note If this field is blank, external static pressure will not be reported for Mode 25. - A250, \field Mode 25 System Second Fuel Consumption Lookup Table Name + A251, \field Mode 25 System Second Fuel Consumption Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the System Second Fuel Consumption Lookup Table for Mode 25. \note Units for lookup table values should be in W. \note If this field is blank, Mode 25 does not consume a second fuel. - A251, \field Mode 25 System Third Fuel Consumption Lookup Table Name + A252, \field Mode 25 System Third Fuel Consumption Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the System Third Fuel Consumption Lookup Table for Mode 25. \note Units for lookup table values should be in W. \note If this field is blank, Mode 25 does not consume a third fuel. - A252, \field Mode 25 System Water Use Lookup Table Name + A253, \field Mode 25 System Water Use Lookup Table Name \type object-list \object-list MultivariateFunctions \note Enter the name of the System Water Use Lookup Table for Mode 25. diff --git a/testfiles/UnitaryHybridAC_DedicatedOutsideAir.idf b/testfiles/UnitaryHybridAC_DedicatedOutsideAir.idf index 34f0b37eff0..01628f05e42 100644 --- a/testfiles/UnitaryHybridAC_DedicatedOutsideAir.idf +++ b/testfiles/UnitaryHybridAC_DedicatedOutsideAir.idf @@ -755,506 +755,7 @@ 1, !- Mode 5 Minimum Outdoor Air Fraction 1, !- Mode 5 Maximum Outdoor Air Fraction 0.729, !- Mode 5 Minimum Supply Air Mass Flow Rate Ratio - 1, !- Mode 5 Maximum Supply Air Mass Flow Rate Ratio - , !- Mode 6 Name - , !- Mode 6 Supply Air Temperature Lookup Table Name - , !- Mode 6 Supply Air Humidity Ratio Lookup Table Name - , !- Mode 6 System Electric Power Lookup Table Name - , !- Mode 6 Supply Fan Electric Power Lookup Table Name - , !- Mode 6 External Static Pressure Lookup Table Name - , !- Mode 6 System Second Fuel Consumption Lookup Table Name - , !- Mode 6 System Third Fuel Consumption Lookup Table Name - , !- Mode 6 System Water Use Lookup Table Name - , !- Mode 6 Minimum Outdoor Air Temperature {C} - , !- Mode 6 Maximum Outdoor Air Temperature {C} - , !- Mode 6 Minimum Outdoor Air Humidity Ratio {kgWater/kgDryAir} - , !- Mode 6 Maximum Outdoor Air Humidity Ratio {kgWater/kgDryAir} - , !- Mode 6 Minimum Outdoor Air Relative Humidity {percent} - , !- Mode 6 Maximum Outdoor Air Relative Humidity {percent} - , !- Mode 6 Minimum Return Air Temperature {C} - , !- Mode 6 Maximum Return Air Temperature {C} - , !- Mode 6 Minimum Return Air Humidity Ratio {kgWater/kgDryAir} - , !- Mode 6 Maximum Return Air Humidity Ratio {kgWater/kgDryAir} - , !- Mode 6 Minimum Return Air Relative Humidity {percent} - , !- Mode 6 Maximum Return Air Relative Humidity {percent} - , !- Mode 6 Minimum Outdoor Air Fraction - , !- Mode 6 Maximum Outdoor Air Fraction - , !- Mode 6 Minimum Supply Air Mass Flow Rate Ratio - , !- Mode 6 Maximum Supply Air Mass Flow Rate Ratio - , !- Mode 7 Name - , !- Mode 7 Supply Air Temperature Lookup Table Name - , !- Mode 7 Supply Air Humidity Ratio Lookup Table Name - , !- Mode 7 System Electric Power Lookup Table Name - , !- Mode 7 Supply Fan Electric Power Lookup Table Name - , !- Mode 7 External Static Pressure Lookup Table Name - , !- Mode 7 System Second Fuel Consumption Lookup Table Name - , !- Mode 7 System Third Fuel Consumption Lookup Table Name - , !- Mode 7 System Water Use Lookup Table Name - , !- Mode 7 Minimum Outdoor Air Temperature {C} - , !- Mode 7 Maximum Outdoor Air Temperature {C} - , !- Mode 7 Minimum Outdoor Air Humidity Ratio {kgWater/kgDryAir} - 0.1, !- Mode 7 Maximum Outdoor Air Humidity Ratio {kgWater/kgDryAir} - , !- Mode 7 Minimum Outdoor Air Relative Humidity {percent} - 100, !- Mode 7 Maximum Outdoor Air Relative Humidity {percent} - , !- Mode 7 Minimum Return Air Temperature {C} - , !- Mode 7 Maximum Return Air Temperature {C} - , !- Mode 7 Minimum Return Air Humidity Ratio {kgWater/kgDryAir} - 0.1, !- Mode 7 Maximum Return Air Humidity Ratio {kgWater/kgDryAir} - , !- Mode 7 Minimum Return Air Relative Humidity {percent} - 100, !- Mode 7 Maximum Return Air Relative Humidity {percent} - 0.1, !- Mode 7 Minimum Outdoor Air Fraction - 1, !- Mode 7 Maximum Outdoor Air Fraction - 0.1, !- Mode 7 Minimum Supply Air Mass Flow Rate Ratio - 1, !- Mode 7 Maximum Supply Air Mass Flow Rate Ratio - , !- Mode 8 Name - , !- Mode 8 Supply Air Temperature Lookup Table Name - , !- Mode 8 Supply Air Humidity Ratio Lookup Table Name - , !- Mode 8 System Electric Power Lookup Table Name - , !- Mode 8 Supply Fan Electric Power Lookup Table Name - , !- Mode 8 External Static Pressure Lookup Table Name - , !- Mode 8 System Second Fuel Consumption Lookup Table Name - , !- Mode 8 System Third Fuel Consumption Lookup Table Name - , !- Mode 8 System Water Use Lookup Table Name - , !- Mode 8 Minimum Outdoor Air Temperature {C} - , !- Mode 8 Maximum Outdoor Air Temperature {C} - , !- Mode 8 Minimum Outdoor Air Humidity Ratio {kgWater/kgDryAir} - 0.1, !- Mode 8 Maximum Outdoor Air Humidity Ratio {kgWater/kgDryAir} - , !- Mode 8 Minimum Outdoor Air Relative Humidity {percent} - 100, !- Mode 8 Maximum Outdoor Air Relative Humidity {percent} - , !- Mode 8 Minimum Return Air Temperature {C} - , !- Mode 8 Maximum Return Air Temperature {C} - , !- Mode 8 Minimum Return Air Humidity Ratio {kgWater/kgDryAir} - 0.1, !- Mode 8 Maximum Return Air Humidity Ratio {kgWater/kgDryAir} - , !- Mode 8 Minimum Return Air Relative Humidity {percent} - 100, !- Mode 8 Maximum Return Air Relative Humidity {percent} - 0.1, !- Mode 8 Minimum Outdoor Air Fraction - 1, !- Mode 8 Maximum Outdoor Air Fraction - 0.1, !- Mode 8 Minimum Supply Air Mass Flow Rate Ratio - 1, !- Mode 8 Maximum Supply Air Mass Flow Rate Ratio - , !- Mode 9 Name - , !- Mode 9 Supply Air Temperature Lookup Table Name - , !- Mode 9 Supply Air Humidity Ratio Lookup Table Name - , !- Mode 9 System Electric Power Lookup Table Name - , !- Mode 9 Supply Fan Electric Power Lookup Table Name - , !- Mode 9 External Static Pressure Lookup Table Name - , !- Mode 9 System Second Fuel Consumption Lookup Table Name - , !- Mode 9 System Third Fuel Consumption Lookup Table Name - , !- Mode 9 System Water Use Lookup Table Name - , !- Mode 9 Minimum Outdoor Air Temperature {C} - , !- Mode 9 Maximum Outdoor Air Temperature {C} - , !- Mode 9 Minimum Outdoor Air Humidity Ratio {kgWater/kgDryAir} - 0.1, !- Mode 9 Maximum Outdoor Air Humidity Ratio {kgWater/kgDryAir} - , !- Mode 9 Minimum Outdoor Air Relative Humidity {percent} - 100, !- Mode 9 Maximum Outdoor Air Relative Humidity {percent} - , !- Mode 9 Minimum Return Air Temperature {C} - , !- Mode 9 Maximum Return Air Temperature {C} - , !- Mode 9 Minimum Return Air Humidity Ratio {kgWater/kgDryAir} - 0.1, !- Mode 9 Maximum Return Air Humidity Ratio {kgWater/kgDryAir} - , !- Mode 9 Minimum Return Air Relative Humidity {percent} - 100, !- Mode 9 Maximum Return Air Relative Humidity {percent} - 0.1, !- Mode 9 Minimum Outdoor Air Fraction - 1, !- Mode 9 Maximum Outdoor Air Fraction - 0.1, !- Mode 9 Minimum Supply Air Mass Flow Rate Ratio - 1, !- Mode 9 Maximum Supply Air Mass Flow Rate Ratio - , !- Mode 10 Name - , !- Mode 10 Supply Air Humidity Ratio Lookup Table Name - , !- Mode 10 System Electric Power Lookup Table Name - , !- Mode 10 Supply Fan Electric Power Lookup Table Name - , !- Mode 10 External Static Pressure Lookup Table Name - , !- Mode 10 System Second Fuel Consumption Lookup Table Name - , !- Mode 10 System Third Fuel Consumption Lookup Table Name - , !- Mode 10 System Water Use Lookup Table Name - , !- Mode 10 Minimum Outdoor Air Temperature {C} - , !- Mode 10 Maximum Outdoor Air Temperature {C} - , !- Mode 10 Minimum Outdoor Air Humidity Ratio {kgWater/kgDryAir} - 0.1, !- Mode 10 Maximum Outdoor Air Humidity Ratio {kgWater/kgDryAir} - , !- Mode 10 Minimum Outdoor Air Relative Humidity {percent} - 100, !- Mode 10 Maximum Outdoor Air Relative Humidity {percent} - , !- Mode 10 Minimum Return Air Temperature {C} - , !- Mode 10 Maximum Return Air Temperature {C} - , !- Mode 10 Minimum Return Air Humidity Ratio {kgWater/kgDryAir} - 0.1, !- Mode 10 Maximum Return Air Humidity Ratio {kgWater/kgDryAir} - , !- Mode 10 Minimum Return Air Relative Humidity {percent} - 100, !- Mode 10 Maximum Return Air Relative Humidity {percent} - 0.1, !- Mode 10 Minimum Outdoor Air Fraction - 1, !- Mode 10 Maximum Outdoor Air Fraction - 0.1, !- Mode 10 Minimum Supply Air Mass Flow Rate Ratio - 1, !- Mode 10 Maximum Supply Air Mass Flow Rate Ratio - , !- Mode 11 Name - , !- Mode 11 Supply Air Temperature Lookup Table Name - , !- Mode 11 Supply Air Humidity Ratio Lookup Table Name - , !- Mode 11 System Electric Power Lookup Table Name - , !- Mode 11 Supply Fan Electric Power Lookup Table Name - , !- Mode 11 External Static Pressure Lookup Table Name - , !- Mode 11 System Second Fuel Consumption Lookup Table Name - , !- Mode 11 System Third Fuel Consumption Lookup Table Name - , !- Mode 11 System Water Use Lookup Table Name - , !- Mode 11 Minimum Outdoor Air Temperature {C} - , !- Mode 11 Maximum Outdoor Air Temperature {C} - , !- Mode 11 Minimum Outdoor Air Humidity Ratio {kgWater/kgDryAir} - 0.1, !- Mode 11 Maximum Outdoor Air Humidity Ratio {kgWater/kgDryAir} - , !- Mode 11 Minimum Outdoor Air Relative Humidity {percent} - 100, !- Mode 11 Maximum Outdoor Air Relative Humidity {percent} - , !- Mode 11 Minimum Return Air Temperature {C} - , !- Mode 11 Maximum Return Air Temperature {C} - , !- Mode 11 Minimum Return Air Humidity Ratio {kgWater/kgDryAir} - 0.1, !- Mode 11 Maximum Return Air Humidity Ratio {kgWater/kgDryAir} - , !- Mode 11 Minimum Return Air Relative Humidity {percent} - 100, !- Mode 11 Maximum Return Air Relative Humidity {percent} - 0.1, !- Mode 11 Minimum Outdoor Air Fraction - 1, !- Mode 11 Maximum Outdoor Air Fraction - 0.1, !- Mode 11 Minimum Supply Air Mass Flow Rate Ratio - 1, !- Mode 11 Maximum Supply Air Mass Flow Rate Ratio - , !- Mode 12 Name - , !- Mode 12 Supply Air Temperature Lookup Table Name - , !- Mode 12 Supply Air Humidity Ratio Lookup Table Name - , !- Mode 12 System Electric Power Lookup Table Name - , !- Mode 12 Supply Fan Electric Power Lookup Table Name - , !- Mode 12 External Static Pressure Lookup Table Name - , !- Mode 12 System Second Fuel Consumption Lookup Table Name - , !- Mode 12 System Third Fuel Consumption Lookup Table Name - , !- Mode 12 System Water Use Lookup Table Name - , !- Mode 12 Minimum Outdoor Air Temperature {C} - , !- Mode 12 Maximum Outdoor Air Temperature {C} - , !- Mode 12 Minimum Outdoor Air Humidity Ratio {kgWater/kgDryAir} - 0.1, !- Mode 12 Maximum Outdoor Air Humidity Ratio {kgWater/kgDryAir} - , !- Mode 12 Minimum Outdoor Air Relative Humidity {percent} - 100, !- Mode 12 Maximum Outdoor Air Relative Humidity {percent} - , !- Mode 12 Minimum Return Air Temperature {C} - , !- Mode 12 Maximum Return Air Temperature {C} - , !- Mode 12 Minimum Return Air Humidity Ratio {kgWater/kgDryAir} - 0.1, !- Mode 12 Maximum Return Air Humidity Ratio {kgWater/kgDryAir} - , !- Mode 12 Minimum Return Air Relative Humidity {percent} - 100, !- Mode 12 Maximum Return Air Relative Humidity {percent} - 0.1, !- Mode 12 Minimum Outdoor Air Fraction - 1, !- Mode 12 Maximum Outdoor Air Fraction - 0.1, !- Mode 12 Minimum Supply Air Mass Flow Rate Ratio - 1, !- Mode 12 Maximum Supply Air Mass Flow Rate Ratio - , !- Mode 13 Name - , !- Mode 13 Supply Air Temperature Lookup Table Name - , !- Mode 13 Supply Air Humidity Ratio Lookup Table Name - , !- Mode 13 System Electric Power Lookup Table Name - , !- Mode 13 Supply Fan Electric Power Lookup Table Name - , !- Mode 13 External Static Pressure Lookup Table Name - , !- Mode 13 System Second Fuel Consumption Lookup Table Name - , !- Mode 13 System Third Fuel Consumption Lookup Table Name - , !- Mode 13 System Water Use Lookup Table Name - , !- Mode 13 Minimum Outdoor Air Temperature {C} - , !- Mode 13 Maximum Outdoor Air Temperature {C} - , !- Mode 13 Minimum Outdoor Air Humidity Ratio {kgWater/kgDryAir} - 0.1, !- Mode 13 Maximum Outdoor Air Humidity Ratio {kgWater/kgDryAir} - , !- Mode 13 Minimum Outdoor Air Relative Humidity {percent} - 100, !- Mode 13 Maximum Outdoor Air Relative Humidity {percent} - , !- Mode 13 Minimum Return Air Temperature {C} - , !- Mode 13 Maximum Return Air Temperature {C} - , !- Mode 13 Minimum Return Air Humidity Ratio {kgWater/kgDryAir} - 0.1, !- Mode 13 Maximum Return Air Humidity Ratio {kgWater/kgDryAir} - , !- Mode 13 Minimum Return Air Relative Humidity {percent} - 100, !- Mode 13 Maximum Return Air Relative Humidity {percent} - 0.1, !- Mode 13 Minimum Outdoor Air Fraction - 1, !- Mode 13 Maximum Outdoor Air Fraction - 0.1, !- Mode 13 Minimum Supply Air Mass Flow Rate Ratio - 1, !- Mode 13 Maximum Supply Air Mass Flow Rate Ratio - , !- Mode 14 Name - , !- Mode 14 Supply Air Temperature Lookup Table Name - , !- Mode 14 Supply Air Humidity Ratio Lookup Table Name - , !- Mode 14 System Electric Power Lookup Table Name - , !- Mode 14 Supply Fan Electric Power Lookup Table Name - , !- Mode 14 External Static Pressure Lookup Table Name - , !- Mode 14 System Second Fuel Consumption Lookup Table Name - , !- Mode 14 System Third Fuel Consumption Lookup Table Name - , !- Mode 14 System Water Use Lookup Table Name - , !- Mode 14 Minimum Outdoor Air Temperature {C} - , !- Mode 14 Maximum Outdoor Air Temperature {C} - , !- Mode 14 Minimum Outdoor Air Humidity Ratio {kgWater/kgDryAir} - 0.1, !- Mode 14 Maximum Outdoor Air Humidity Ratio {kgWater/kgDryAir} - , !- Mode 14 Minimum Outdoor Air Relative Humidity {percent} - 100, !- Mode 14 Maximum Outdoor Air Relative Humidity {percent} - , !- Mode 14 Minimum Return Air Temperature {C} - , !- Mode 14 Maximum Return Air Temperature {C} - , !- Mode 14 Minimum Return Air Humidity Ratio {kgWater/kgDryAir} - 0.1, !- Mode 14 Maximum Return Air Humidity Ratio {kgWater/kgDryAir} - , !- Mode 14 Minimum Return Air Relative Humidity {percent} - 100, !- Mode 14 Maximum Return Air Relative Humidity {percent} - 0.1, !- Mode 14 Minimum Outdoor Air Fraction - 1, !- Mode 14 Maximum Outdoor Air Fraction - 0.1, !- Mode 14 Minimum Supply Air Mass Flow Rate Ratio - 1, !- Mode 14 Maximum Supply Air Mass Flow Rate Ratio - , !- Mode 15 Name - , !- Mode 15 Supply Air Temperature Lookup Table Name - , !- Mode 15 Supply Air Humidity Ratio Lookup Table Name - , !- Mode 15 System Electric Power Lookup Table Name - , !- Mode 15 Supply Fan Electric Power Lookup Table Name - , !- Mode 15 External Static Pressure Lookup Table Name - , !- Mode 15 System Second Fuel Consumption Lookup Table Name - , !- Mode 15 System Third Fuel Consumption Lookup Table Name - , !- Mode 15 System Water Use Lookup Table Name - , !- Mode 15 Minimum Outdoor Air Temperature {C} - , !- Mode 15 Maximum Outdoor Air Temperature {C} - , !- Mode 15 Minimum Outdoor Air Humidity Ratio {kgWater/kgDryAir} - 0.1, !- Mode 15 Maximum Outdoor Air Humidity Ratio {kgWater/kgDryAir} - , !- Mode 15 Minimum Outdoor Air Relative Humidity {percent} - 100, !- Mode 15 Maximum Outdoor Air Relative Humidity {percent} - , !- Mode 15 Minimum Return Air Temperature {C} - , !- Mode 15 Maximum Return Air Temperature {C} - , !- Mode 15 Minimum Return Air Humidity Ratio {kgWater/kgDryAir} - 0.1, !- Mode 15 Maximum Return Air Humidity Ratio {kgWater/kgDryAir} - , !- Mode 15 Minimum Return Air Relative Humidity {percent} - 100, !- Mode 15 Maximum Return Air Relative Humidity {percent} - 0.1, !- Mode 15 Minimum Outdoor Air Fraction - 1, !- Mode 15 Maximum Outdoor Air Fraction - 0.1, !- Mode 15 Minimum Supply Air Mass Flow Rate Ratio - 1, !- Mode 15 Maximum Supply Air Mass Flow Rate Ratio - , !- Mode 16 Name - , !- Mode 16 Supply Air Temperature Lookup Table Name - , !- Mode 16 Supply Air Humidity Ratio Lookup Table Name - , !- Mode 16 System Electric Power Lookup Table Name - , !- Mode 16 Supply Fan Electric Power Lookup Table Name - , !- Mode 16 External Static Pressure Lookup Table Name - , !- Mode 16 System Second Fuel Consumption Lookup Table Name - , !- Mode 16 System Third Fuel Consumption Lookup Table Name - , !- Mode 16 System Water Use Lookup Table Name - , !- Mode 16 Minimum Outdoor Air Temperature {C} - , !- Mode 16 Maximum Outdoor Air Temperature {C} - , !- Mode 16 Minimum Outdoor Air Humidity Ratio {kgWater/kgDryAir} - 0.1, !- Mode 16 Maximum Outdoor Air Humidity Ratio {kgWater/kgDryAir} - , !- Mode 16 Minimum Outdoor Air Relative Humidity {percent} - 100, !- Mode 16 Maximum Outdoor Air Relative Humidity {percent} - , !- Mode 16 Minimum Return Air Temperature {C} - , !- Mode 16 Maximum Return Air Temperature {C} - , !- Mode 16 Minimum Return Air Humidity Ratio {kgWater/kgDryAir} - 0.1, !- Mode 16 Maximum Return Air Humidity Ratio {kgWater/kgDryAir} - , !- Mode 16 Minimum Return Air Relative Humidity {percent} - 100, !- Mode 16 Maximum Return Air Relative Humidity {percent} - 0.1, !- Mode 16 Minimum Outdoor Air Fraction - 1, !- Mode 16 Maximum Outdoor Air Fraction - 0.1, !- Mode 16 Minimum Supply Air Mass Flow Rate Ratio - 1, !- Mode 16 Maximum Supply Air Mass Flow Rate Ratio - , !- Mode 17 Name - , !- Mode 17 Supply Air Temperature Lookup Table Name - , !- Mode 17 Supply Air Humidity Ratio Lookup Table Name - , !- Mode 17 System Electric Power Lookup Table Name - , !- Mode 17 Supply Fan Electric Power Lookup Table Name - , !- Mode 17 External Static Pressure Lookup Table Name - , !- Mode 17 System Second Fuel Consumption Lookup Table Name - , !- Mode 17 System Third Fuel Consumption Lookup Table Name - , !- Mode 17 System Water Use Lookup Table Name - , !- Mode 17 Minimum Outdoor Air Temperature {C} - , !- Mode 17 Maximum Outdoor Air Temperature {C} - , !- Mode 17 Minimum Outdoor Air Humidity Ratio {kgWater/kgDryAir} - 0.1, !- Mode 17 Maximum Outdoor Air Humidity Ratio {kgWater/kgDryAir} - , !- Mode 17 Minimum Outdoor Air Relative Humidity {percent} - 100, !- Mode 17 Maximum Outdoor Air Relative Humidity {percent} - , !- Mode 17 Minimum Return Air Temperature {C} - , !- Mode 17 Maximum Return Air Temperature {C} - , !- Mode 17 Minimum Return Air Humidity Ratio {kgWater/kgDryAir} - 0.1, !- Mode 17 Maximum Return Air Humidity Ratio {kgWater/kgDryAir} - , !- Mode 17 Minimum Return Air Relative Humidity {percent} - 100, !- Mode 17 Maximum Return Air Relative Humidity {percent} - 0.1, !- Mode 17 Minimum Outdoor Air Fraction - 1, !- Mode 17 Maximum Outdoor Air Fraction - 0.1, !- Mode 17 Minimum Supply Air Mass Flow Rate Ratio - 1, !- Mode 17 Maximum Supply Air Mass Flow Rate Ratio - , !- Mode 18 Name - , !- Mode 18 Supply Air Temperature Lookup Table Name - , !- Mode 18 Supply Air Humidity Ratio Lookup Table Name - , !- Mode 18 System Electric Power Lookup Table Name - , !- Mode 18 Supply Fan Electric Power Lookup Table Name - , !- Mode 18 External Static Pressure Lookup Table Name - , !- Mode 18 System Second Fuel Consumption Lookup Table Name - , !- Mode 18 System Third Fuel Consumption Lookup Table Name - , !- Mode 18 System Water Use Lookup Table Name - , !- Mode 18 Minimum Outdoor Air Temperature {C} - , !- Mode 18 Maximum Outdoor Air Temperature {C} - , !- Mode 18 Minimum Outdoor Air Humidity Ratio {kgWater/kgDryAir} - 0.1, !- Mode 18 Maximum Outdoor Air Humidity Ratio {kgWater/kgDryAir} - , !- Mode 18 Minimum Outdoor Air Relative Humidity {percent} - 100, !- Mode 18 Maximum Outdoor Air Relative Humidity {percent} - , !- Mode 18 Minimum Return Air Temperature {C} - , !- Mode 18 Maximum Return Air Temperature {C} - , !- Mode 18 Minimum Return Air Humidity Ratio {kgWater/kgDryAir} - 0.1, !- Mode 18 Maximum Return Air Humidity Ratio {kgWater/kgDryAir} - , !- Mode 18 Minimum Return Air Relative Humidity {percent} - 100, !- Mode 18 Maximum Return Air Relative Humidity {percent} - 0.1, !- Mode 18 Minimum Outdoor Air Fraction - 1, !- Mode 18 Maximum Outdoor Air Fraction - 0.1, !- Mode 18 Minimum Supply Air Mass Flow Rate Ratio - 1, !- Mode 18 Maximum Supply Air Mass Flow Rate Ratio - , !- Mode 19 Name - , !- Mode 19 Supply Air Temperature Lookup Table Name - , !- Mode 19 Supply Air Humidity Ratio Lookup Table Name - , !- Mode 19 System Electric Power Lookup Table Name - , !- Mode 19 Supply Fan Electric Power Lookup Table Name - , !- Mode 19 External Static Pressure Lookup Table Name - , !- Mode 19 System Second Fuel Consumption Lookup Table Name - , !- Mode 19 System Third Fuel Consumption Lookup Table Name - , !- Mode 19 System Water Use Lookup Table Name - , !- Mode 19 Minimum Outdoor Air Temperature {C} - , !- Mode 19 Maximum Outdoor Air Temperature {C} - , !- Mode 19 Minimum Outdoor Air Humidity Ratio {kgWater/kgDryAir} - 0.1, !- Mode 19 Maximum Outdoor Air Humidity Ratio {kgWater/kgDryAir} - , !- Mode 19 Minimum Outdoor Air Relative Humidity {percent} - 100, !- Mode 19 Maximum Outdoor Air Relative Humidity {percent} - , !- Mode 19 Minimum Return Air Temperature {C} - , !- Mode 19 Maximum Return Air Temperature {C} - , !- Mode 19 Minimum Return Air Humidity Ratio {kgWater/kgDryAir} - 0.1, !- Mode 19 Maximum Return Air Humidity Ratio {kgWater/kgDryAir} - , !- Mode 19 Minimum Return Air Relative Humidity {percent} - 100, !- Mode 19 Maximum Return Air Relative Humidity {percent} - 0.1, !- Mode 19 Minimum Outdoor Air Fraction - 1, !- Mode 19 Maximum Outdoor Air Fraction - 0.1, !- Mode 19 Minimum Supply Air Mass Flow Rate Ratio - 1, !- Mode 19 Maximum Supply Air Mass Flow Rate Ratio - , !- Mode 20 Name - , !- Mode 20 Supply Air Temperature Lookup Table Name - , !- Mode 20 Supply Air Humidity Ratio Lookup Table Name - , !- Mode 20 System Electric Power Lookup Table Name - , !- Mode 20 Supply Fan Electric Power Lookup Table Name - , !- Mode 20 External Static Pressure Lookup Table Name - , !- Mode 20 System Second Fuel Consumption Lookup Table Name - , !- Mode 20 System Third Fuel Consumption Lookup Table Name - , !- Mode 20 System Water Use Lookup Table Name - , !- Mode 20 Minimum Outdoor Air Temperature {C} - , !- Mode 20 Maximum Outdoor Air Temperature {C} - , !- Mode 20 Minimum Outdoor Air Humidity Ratio {kgWater/kgDryAir} - 0.1, !- Mode 20 Maximum Outdoor Air Humidity Ratio {kgWater/kgDryAir} - , !- Mode 20 Minimum Outdoor Air Relative Humidity {percent} - 100, !- Mode 20 Maximum Outdoor Air Relative Humidity {percent} - , !- Mode 20 Minimum Return Air Temperature {C} - , !- Mode 20 Maximum Return Air Temperature {C} - , !- Mode 20 Minimum Return Air Humidity Ratio {kgWater/kgDryAir} - 0.1, !- Mode 20 Maximum Return Air Humidity Ratio {kgWater/kgDryAir} - , !- Mode 20 Minimum Return Air Relative Humidity {percent} - 100, !- Mode 20 Maximum Return Air Relative Humidity {percent} - 0.1, !- Mode 20 Minimum Outdoor Air Fraction - 1, !- Mode 20 Maximum Outdoor Air Fraction - 0.1, !- Mode 20 Minimum Supply Air Mass Flow Rate Ratio - 1, !- Mode 20 Maximum Supply Air Mass Flow Rate Ratio - , !- Mode 21 Name - , !- Mode 21 Supply Air Temperature Lookup Table Name - , !- Mode 21 Supply Air Humidity Ratio Lookup Table Name - , !- Mode 21 System Electric Power Lookup Table Name - , !- Mode 21 Supply Fan Electric Power Lookup Table Name - , !- Mode 21 External Static Pressure Lookup Table Name - , !- Mode 21 System Second Fuel Consumption Lookup Table Name - , !- Mode 21 System Third Fuel Consumption Lookup Table Name - , !- Mode 21 System Water Use Lookup Table Name - , !- Mode 21 Minimum Outdoor Air Temperature {C} - , !- Mode 21 Maximum Outdoor Air Temperature {C} - , !- Mode 21 Minimum Outdoor Air Humidity Ratio {kgWater/kgDryAir} - 0.1, !- Mode 21 Maximum Outdoor Air Humidity Ratio {kgWater/kgDryAir} - , !- Mode 21 Minimum Outdoor Air Relative Humidity {percent} - 100, !- Mode 21 Maximum Outdoor Air Relative Humidity {percent} - , !- Mode 21 Minimum Return Air Temperature {C} - , !- Mode 21 Maximum Return Air Temperature {C} - , !- Mode 21 Minimum Return Air Humidity Ratio {kgWater/kgDryAir} - 0.1, !- Mode 21 Maximum Return Air Humidity Ratio {kgWater/kgDryAir} - , !- Mode 21 Minimum Return Air Relative Humidity {percent} - 100, !- Mode 21 Maximum Return Air Relative Humidity {percent} - 0.1, !- Mode 21 Minimum Outdoor Air Fraction - 1, !- Mode 21 Maximum Outdoor Air Fraction - 0.1, !- Mode 21 Minimum Supply Air Mass Flow Rate Ratio - 1, !- Mode 21 Maximum Supply Air Mass Flow Rate Ratio - , !- Mode 22 Name - , !- Mode 22 Supply Air Temperature Lookup Table Name - , !- Mode 22 Supply Air Humidity Ratio Lookup Table Name - , !- Mode 22 System Electric Power Lookup Table Name - , !- Mode 22 Supply Fan Electric Power Lookup Table Name - , !- Mode 22 External Static Pressure Lookup Table Name - , !- Mode 22 System Second Fuel Consumption Lookup Table Name - , !- Mode 22 System Third Fuel Consumption Lookup Table Name - , !- Mode 22 System Water Use Lookup Table Name - , !- Mode 22 Minimum Outdoor Air Temperature {C} - , !- Mode 22 Maximum Outdoor Air Temperature {C} - , !- Mode 22 Minimum Outdoor Air Humidity Ratio {kgWater/kgDryAir} - 0.1, !- Mode 22 Maximum Outdoor Air Humidity Ratio {kgWater/kgDryAir} - , !- Mode 22 Minimum Outdoor Air Relative Humidity {percent} - 100, !- Mode 22 Maximum Outdoor Air Relative Humidity {percent} - , !- Mode 22 Minimum Return Air Temperature {C} - , !- Mode 22 Maximum Return Air Temperature {C} - , !- Mode 22 Minimum Return Air Humidity Ratio {kgWater/kgDryAir} - 0.1, !- Mode 22 Maximum Return Air Humidity Ratio {kgWater/kgDryAir} - , !- Mode 22 Minimum Return Air Relative Humidity {percent} - 100, !- Mode 22 Maximum Return Air Relative Humidity {percent} - 0.1, !- Mode 22 Minimum Outdoor Air Fraction - 1, !- Mode 22 Maximum Outdoor Air Fraction - 0.1, !- Mode 22 Minimum Supply Air Mass Flow Rate Ratio - 1, !- Mode 22 Maximum Supply Air Mass Flow Rate Ratio - , !- Mode 23 Name - , !- Mode 23 Supply Air Temperature Lookup Table Name - , !- Mode 23 Supply Air Humidity Ratio Lookup Table Name - , !- Mode 23 System Electric Power Lookup Table Name - , !- Mode 23 Supply Fan Electric Power Lookup Table Name - , !- Mode 23 External Static Pressure Lookup Table Name - , !- Mode 23 System Second Fuel Consumption Lookup Table Name - , !- Mode 23 System Third Fuel Consumption Lookup Table Name - , !- Mode 23 System Water Use Lookup Table Name - , !- Mode 23 Minimum Outdoor Air Temperature {C} - , !- Mode 23 Maximum Outdoor Air Temperature {C} - , !- Mode 23 Minimum Outdoor Air Humidity Ratio {kgWater/kgDryAir} - 0.1, !- Mode 23 Maximum Outdoor Air Humidity Ratio {kgWater/kgDryAir} - , !- Mode 23 Minimum Outdoor Air Relative Humidity {percent} - 100, !- Mode 23 Maximum Outdoor Air Relative Humidity {percent} - , !- Mode 23 Minimum Return Air Temperature {C} - , !- Mode 23 Maximum Return Air Temperature {C} - , !- Mode 23 Minimum Return Air Humidity Ratio {kgWater/kgDryAir} - 0.1, !- Mode 23 Maximum Return Air Humidity Ratio {kgWater/kgDryAir} - , !- Mode 23 Minimum Return Air Relative Humidity {percent} - 100, !- Mode 23 Maximum Return Air Relative Humidity {percent} - 0.1, !- Mode 23 Minimum Outdoor Air Fraction - 1, !- Mode 23 Maximum Outdoor Air Fraction - 0.1, !- Mode 23 Minimum Supply Air Mass Flow Rate Ratio - 1, !- Mode 23 Maximum Supply Air Mass Flow Rate Ratio - , !- Mode 24 Name - , !- Mode 24 Supply Air Temperature Lookup Table Name - , !- Mode 24 Supply Air Humidity Ratio Lookup Table Name - , !- Mode 24 System Electric Power Lookup Table Name - , !- Mode 24 Supply Fan Electric Power Lookup Table Name - , !- Mode 24 External Static Pressure Lookup Table Name - , !- Mode 24 System Second Fuel Consumption Lookup Table Name - , !- Mode 24 System Third Fuel Consumption Lookup Table Name - , !- Mode 24 System Water Use Lookup Table Name - , !- Mode 24 Minimum Outdoor Air Temperature {C} - , !- Mode 24 Maximum Outdoor Air Temperature {C} - , !- Mode 24 Minimum Outdoor Air Humidity Ratio {kgWater/kgDryAir} - 0.1, !- Mode 24 Maximum Outdoor Air Humidity Ratio {kgWater/kgDryAir} - , !- Mode 24 Minimum Outdoor Air Relative Humidity {percent} - 100, !- Mode 24 Maximum Outdoor Air Relative Humidity {percent} - , !- Mode 24 Minimum Return Air Temperature {C} - , !- Mode 24 Maximum Return Air Temperature {C} - , !- Mode 24 Minimum Return Air Humidity Ratio {kgWater/kgDryAir} - 0.1, !- Mode 24 Maximum Return Air Humidity Ratio {kgWater/kgDryAir} - , !- Mode 24 Minimum Return Air Relative Humidity {percent} - 100, !- Mode 24 Maximum Return Air Relative Humidity {percent} - 0.1, !- Mode 24 Minimum Outdoor Air Fraction - 1, !- Mode 24 Maximum Outdoor Air Fraction - 0.1, !- Mode 24 Minimum Supply Air Mass Flow Rate Ratio - 1, !- Mode 24 Maximum Supply Air Mass Flow Rate Ratio - , !- Mode 25 Name - , !- Mode 25 Supply Air Temperature Lookup Table Name - , !- Mode 25 Supply Air Humidity Ratio Lookup Table Name - , !- Mode 25 System Electric Power Lookup Table Name - , !- Mode 25 Supply Fan Electric Power Lookup Table Name - , !- Mode 25 External Static Pressure Lookup Table Name - , !- Mode 25 System Second Fuel Consumption Lookup Table Name - , !- Mode 25 System Third Fuel Consumption Lookup Table Name - , !- Mode 25 System Water Use Lookup Table Name - , !- Mode 25 Minimum Outdoor Air Temperature {C} - , !- Mode 25 Maximum Outdoor Air Temperature {C} - , !- Mode 25 Minimum Outdoor Air Humidity Ratio {kgWater/kgDryAir} - 0.1, !- Mode 25 Maximum Outdoor Air Humidity Ratio {kgWater/kgDryAir} - , !- Mode 25 Minimum Outdoor Air Relative Humidity {percent} - 100, !- Mode 25 Maximum Outdoor Air Relative Humidity {percent} - , !- Mode 25 Minimum Return Air Temperature {C} - , !- Mode 25 Maximum Return Air Temperature {C} - , !- Mode 25 Minimum Return Air Humidity Ratio {kgWater/kgDryAir} - 0.1, !- Mode 25 Maximum Return Air Humidity Ratio {kgWater/kgDryAir} - , !- Mode 25 Minimum Return Air Relative Humidity {percent} - 100, !- Mode 25 Maximum Return Air Relative Humidity {percent} - 0.1, !- Mode 25 Minimum Outdoor Air Fraction - 1, !- Mode 25 Maximum Outdoor Air Fraction - 0.1, !- Mode 25 Minimum Supply Air Mass Flow Rate Ratio - 1; !- Mode 25 Maximum Supply Air Mass Flow Rate Ratio + 1; !- Mode 5 Maximum Supply Air Mass Flow Rate Ratio !- =========== ALL OBJECTS IN CLASS: ZONEHVAC:EQUIPMENTCONNECTIONS ===========