Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

CO₂ Sequestration During WAG Simulation #5619

Open
loveduah1 opened this issue Sep 19, 2024 · 2 comments
Open

CO₂ Sequestration During WAG Simulation #5619

loveduah1 opened this issue Sep 19, 2024 · 2 comments

Comments

@loveduah1
Copy link

Hello,

I’m trying to determine the amount of CO₂ sequestered during WAG, but I encountered the following error from the START.DATA file. The WAG.DATA file runs, but the FNIT-FNPT values are consistently zero. Could you please advise on how to resolve these issues?

Error Details:

  • Processing grid: Total active cells = 363, Total pore volume = 160,016,327 RB
  • Simulation aborted due to unexpected exception: "Could not allocate the problem: TableContainer does not have any table in the range 0...0."

Attached are the input files for reference.

Thank you for your assistance.

GIP.zip

@totto82
Copy link
Member

totto82 commented Sep 20, 2024

For the START.DATA you need to set
SSFN
0.0 0.0 0.0
1.0 1.0 1.0
/
(this was commented out in your input deck)

I will add a more proper default/error message so you would get a more readable message next time.

For the WAG.DATA case is seems your gas well is always set to shut.

@loveduah1
Copy link
Author

Thank you

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment