Frame structure

AA XX YY .. YY ZZ

  • AA - Magic prefix. Fixed to 0xAA
  • XX - Size of YY packet in bytes
  • YY .. YY - Data packet
  • ZZ - CRC. Sum of AA+XX+YY..YY, clipped to byte.

Packet Structure

XX YY .. YY

  • XX - Required. Command.
  • YY - Optional. Command data structure.

Request commands (from user to device)

Some of request commands have corresponding response with 0x80 mask.

01 - Device/manufacturer identification

Zero body.

Returns response command 81 with device/manufacturer identification data.

00.00.00.00.00.11 Electrolux EWH
00.00.00.00.00.04 Ballu BWH
00.00.00.00.01.05 Electrolux ETS-16

This command is executed from cloud server every time it connects to device.

This command will not executed from cloud server if pairing process already completed and 87 command result is not equals data saved by 06 command call.

06 - Save Data (?)

any 16 bytes data structure.

Returns command 86 with 1 byte body, 01 means OK, 00 means ERROR. Later this data can be loaded via `07' command.

This command used in cloud device pairing process.

07 - Load Data (?)

Zero body.

This command is executed from cloud server every time it connects to device. Before pairing process the all data must be filled with zeroes.

Returns response with command 87 with 16 bytes data structure.

00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 (initital cloud data)
00.00.00.00.00.00.00.00.00.00.00.00.00.1a.25.04 (cloud data with cloud UID triplet, this sample is 263704)

08 - Request device state

Unknown 2 bytes data structure with fixed value.

10 04

Note: Also will work with zero bytes body.

Returns response with 88 command.

0A - Change device state

First byte is operation, one of:

  • 0 - change mode
  • 1 - change clock
  • 2 - change timer
  • 3 - change bst

Note: do not return value, so you need to request state via 08 command.

00 - Change mode structure

  • byte mode - 0 - off, 1 - 700W, 2 - 1300W, 3 - 2000W, 4 - no frost
  • byte temperature

01 - Change clock

  • byte hours
  • byte minutes

02 - Change timer

  • byte hours
  • byte minutes
  • byte mode - probably mode (1 - 700W, 2 - 1300W, 3 - 2000W), but from app it is always 1
  • byte tempearture

03 - Change bst

  • byte state - 0 - off, 1 - on

Response commands (from device to user)

05 - Error

  • code - 1 - no error, 1 - invlid CRC, 2 - invalid command

09 - Device state (Electrolux)

Received every 30 seconds.

  • byte state - 0 - off, 1 - 700W, 2 - 1300W, 3 - 2000W, 4 - timer, 5 - no frost
  • byte current_temperature
  • byte target_temperature
  • byte clock_hours
  • byte clock_minutes
  • byte timer_hours
  • byte timer_minutes
  • byte error - 0 - no error, 1 - temperature sensor error, 2-255 - other error
  • byte bst - 0 - off, 1 - enabled

09 - Device state (Ballu)

Received every 30 seconds.

  • byte state - 0 - off, 1 - 1300W, 2 - 2000W
  • byte current_temperature
  • byte target_temperature
  • byte unknown - known value 00
  • byte unknown - known value 00
  • byte unknown - known value 04
  • byte unknown - known value 00
  • byte error - 0 - no error, 1 - temperature sensor error, 2-255 - other error

88 - Device state

Response to request of 08 command.

Structure is the same as in [09 command].