PPS measurement setup

Enable PPS output

You can output a PPS signal driven by the PHC clock on the SYNC_OUT pin, which you can then measure on an external device (e.g. oscilloscope or logic analyzer).

# Configure SYNC_OUT pin for periodic output
sudo ./testptp -d /dev/ptp0 -L 0,2
# Generate pulse of width 1us every second
sudo ./testptp -d /dev/ptp0 -p 1000000000 -w 1000

The -p argument gives the time between the start of each pulse in nanoseconds; the only acceptable values are 1000000000, meaning 1 second, and 0, meaning to stop generating pulses. The -w argument gives the width of the pulse in nanoseconds; the maximum value, which is also the default, is 4095, meaning just over 4 microseconds.

Measure PPS output

If you have an oscilloscope, you can of course use that. Bear in mind that the PPS pulse width generated is much shorter than usual. (Typical PPS width from a GPS is 100ms, whereas this is 0.004ms.)

If you do not possess any suitable measuring equipment, the cheapest way to see the pulse is to use sigrok with a cheap Cypress FX2-based logic analyzer. These are available for about $10 on AliExpress: search for "USB 24MHz 8 channel logic analyzer".

The TAPR TICC looks like a good option for doing much more precise measurements, at a relatively affordable price.