diff --git a/RFElasto3D/postCompressed/image00000.mhd b/RFElasto3D/postCompressed/image00000.mhd new file mode 100644 index 0000000..547ca95 --- /dev/null +++ b/RFElasto3D/postCompressed/image00000.mhd @@ -0,0 +1,28 @@ +NDims = 3 +DimSize = 128 7680 15 +ElementSpacing = 1.000000 1.000000 1.000000 +ElementType = MET_SHORT +ElementByteOrderMSB = 0 +ElementDataFile = image00000.raw +Comment = Availables ultrasound image types are RF_2D, RF_3D, PRESCAN_2D, PRESCAN_3D, POSTSCAN_2D and POSTSCAN_3D. +UltrasoundImageType = RF_3D +Comment = True if probe transducer is convex, false if linear. +IsTransducerConvex = 1 +Comment = Radius between the scan lines intersection and the first pixel of each line acquired. 0 if linear probe. +TransducerRadius = 3.980000e-02 +Comment = Distance between 2 scan lines. +ScanLinePitch = 1.067839e-02 +Comment = Frequency of the ultrasound wave sent (Hz). +TransmitFrequency = 4500000 +Comment = Frequency used to sample the ultrasound wave received (Hz). +SamplingFrequency = 2500000 +Comment = Probe motor type : LinearMotor, TiltingMotor (for small roatations), or RotationalMotor (for 360 deg rotation). +MotorType = TiltingMotor +Comment = Only in 3d. Radius between the probe motor center and the first pixel of each line acquired. 0 if linear motor. +MotorRadius = 2.725000e-02 +Comment = Only in 3d. Distance between 2 successive frames. +FramePitch = 2.554140e-02 +Comment = The axial resolution is the distance in meters between two successives RF-samples in a scan line. +AxialResolution = 1.953125e-05 +Comment = The frame timestamps are expressed in ms since epoch. +Timestamp = 391 359 328 313 281 250 219 188 172 141 109 78 63 31 0 diff --git a/RFElasto3D/postCompressed/image00000.raw b/RFElasto3D/postCompressed/image00000.raw new file mode 100644 index 0000000..f2dc974 Binary files /dev/null and b/RFElasto3D/postCompressed/image00000.raw differ diff --git a/RFElasto3D/preCompressed/image00000.mhd b/RFElasto3D/preCompressed/image00000.mhd new file mode 100644 index 0000000..e714535 --- /dev/null +++ b/RFElasto3D/preCompressed/image00000.mhd @@ -0,0 +1,28 @@ +NDims = 3 +DimSize = 128 7680 15 +ElementSpacing = 1.000000 1.000000 1.000000 +ElementType = MET_SHORT +ElementByteOrderMSB = 0 +ElementDataFile = image00000.raw +Comment = Availables ultrasound image types are RF_2D, RF_3D, PRESCAN_2D, PRESCAN_3D, POSTSCAN_2D and POSTSCAN_3D. +UltrasoundImageType = RF_3D +Comment = True if probe transducer is convex, false if linear. +IsTransducerConvex = 1 +Comment = Radius between the scan lines intersection and the first pixel of each line acquired. 0 if linear probe. +TransducerRadius = 3.980000e-02 +Comment = Distance between 2 scan lines. +ScanLinePitch = 1.067839e-02 +Comment = Frequency of the ultrasound wave sent (Hz). +TransmitFrequency = 4500000 +Comment = Frequency used to sample the ultrasound wave received (Hz). +SamplingFrequency = 2500000 +Comment = Probe motor type : LinearMotor, TiltingMotor (for small roatations), or RotationalMotor (for 360 deg rotation). +MotorType = TiltingMotor +Comment = Only in 3d. Radius between the probe motor center and the first pixel of each line acquired. 0 if linear motor. +MotorRadius = 2.725000e-02 +Comment = Only in 3d. Distance between 2 successive frames. +FramePitch = 2.554140e-02 +Comment = The axial resolution is the distance in meters between two successives RF-samples in a scan line. +AxialResolution = 1.953125e-05 +Comment = The frame timestamps are expressed in ms since epoch. +Timestamp = 390 359 328 297 281 250 218 187 172 140 109 78 62 31 0 diff --git a/RFElasto3D/preCompressed/image00000.raw b/RFElasto3D/preCompressed/image00000.raw new file mode 100644 index 0000000..da85c27 Binary files /dev/null and b/RFElasto3D/preCompressed/image00000.raw differ