Notifications
You must be signed in to change notification settings - Fork 1
/
get_values.py
128 lines (120 loc) · 5.05 KB
/
get_values.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
#!/usr/bin/python
import sys
import socket
from pprint import pprint
from struct import *
from rrdtool import update as rrd_update
import time
LIN="02 FD D0 E0 00 00 05 7E 4C 49 4E 3B 4C" # LOGIN?
RID="02 FD D0 E0 00 00 05 7E 52 49 44 3B 70" # RID?
TEMP_OUT="02 FD D0 E0 00 00 09 7E 4D 50 2C 4E 52 3D 30 3B E5" # AUssentemperatur
TEMP_WATER="02 FD D0 E0 00 00 09 7E 4D 50 2C 4E 52 3D 32 3B E3" # Temperatur Brauchwasser
TEMP_VORL="02 FD D0 E0 00 00 09 7E 4D 50 2C 4E 52 3D 33 3B E0" # Temperatur Vorlauf
TEMP_RUCKL="02 FD D0 E0 00 00 09 7E 4D 50 2C 4E 52 3D 34 3B E9" # Temperatur Ruecklauf
EQ_ENTRY="02 FD D0 E0 00 00 09 7E 4D 50 2C 4E 52 3D 36 3B EF" # EQ Eintritt
EQ_EXIT="02 FD D0 E0 00 00 09 7E 4D 50 2C 4E 52 3D 37 3B EC" # EQ Austritt
TEMP_GAS="02 FD D0 E0 00 00 09 7E 4D 50 2C 4E 52 3D 39 3B FE" # Temperatur Sauggas
COMPR="02 FD D0 E0 00 00 0A 7E 53 50 2C 4E 52 3D 31 30 3B 91" # Status Verdichter: 0 - AUS, 8 - LAEUFT
COMPR_TIME="02 FD D0 E0 00 00 0A 7E 53 50 2C 4E 52 3D 31 31 3B" # Verdichter Zeit
COMPR_REQ="02 FD D0 E0 00 00 0A 7E 4D 50 2C 4E 52 3D 35 36 3B B5" # Verdichter Anforderung
TEMP_FWATER="02 FD D0 E0 00 00 0A 7E 4D 50 2C 4E 52 3D 31 31 3B B0" # Temperatur Frischwasser IST
HEATING_PUMP="02 FD D0 E0 00 00 0A 7E 4D 50 2C 4E 52 3D 32 32 3B B0" # Heizkreispumpe
STATUS_HOTWATER="02 FD D0 E0 00 00 0A 7E 4D 50 2C 4E 52 3D 32 35 3B B9" # STatus Warmwasser Vorrang
TEMP_STEAM="02 FD D0 E0 00 00 0A 7E 4D 50 2C 4E 52 3D 31 32 3B B5" # Temperatur Verdampfung
TEMP_COND="02 FD D0 E0 00 00 0A 7E 4D 50 2C 4E 52 3D 31 33 3B B6" # Temperatur Kondesation
LOW_PRESS="02 FD D0 E0 00 00 0A 7E 4D 50 2C 4E 52 3D 32 30 3B B6" # Niederdruck in bar
HIGH_PRESS="02 FD D0 E0 00 00 0A 7E 4D 50 2C 4E 52 3D 32 31 3B B5" # Hockdruck in bar
HPUMP="02 FD D0 E0 00 00 0A 7E 4D 50 2C 4E 52 3D 32 32 3B B0" # HKR Pumpe
PRIO_WATER="02 FD D0 E0 00 00 0A 7E 4D 50 2C 4E 52 3D 32 35 3B B9" # Status Warmwasser Vorrang
FWATER_PUMP="02 FD D0 E0 00 00 0A 7E 4D 50 2C 4E 52 3D 35 30 3B BF" # Status Frischwasserpumpe
HSHOULD="02 FD D0 E0 00 00 0A 7E 4D 50 2C 4E 52 3D 35 37 3B B6" # Heizkreis Sollwert
OPMODE="02 FD D0 E0 00 00 0A 7E 53 50 2C 4E 52 3D 31 33 3B 94" # Betriebsart: 1 - AUTOMATIK
WNORMAL="02 FD D0 E0 00 00 0A 7E 53 50 2C 4E 52 3D 38 33 3B 8F" # Warmwasser Temp Soll
WMIN="02 FD D0 E0 00 00 0A 7E 53 50 2C 4E 52 3D 38 35 3B 85" # Warmwasser Temp Min
HOURS_COMP_WW="02 FD D0 E0 00 00 0B 7E 53 50 2C 4E 52 3D 31 37 31 3B C8" # Betriebsstunden Verdichter WW
HOURS_COMP_HEAT="02 FD D0 E0 00 00 0B 7E 53 50 2C 4E 52 3D 31 37 32 3B CD" # Betriebsstunden Kompressor Heizung
HOURS_COMP_TOTAL="02 FD D0 E0 00 00 0B 7E 53 50 2C 4E 52 3D 31 37 33 3B CE" # Betriebsstunden Verdichter Gesamt
LOUT="02 FD D0 E0 00 00 06 7E 4C 4F 55 54 3B 92" # LOGOUT
def hexconv(clear):
command = ''
words = clear.split()
for word in words:
command += chr(int(word, 16))
return command
def query(command):
s.send(hexconv(command))
time.sleep(1)
response=s.recv(8192)
#print (response,10)
words = response.split(',')
for word in words:
if "NAME" in word:
print word
if "VAL" in word:
print word
def update_rrd(commands):
values = []
responses = []
for command in commands:
s.send(hexconv(command))
time.sleep(1)
responses.append(s.recv(8192))
for response in responses:
words = response.split(',')
for word in words:
if "NAME" in word:
print word
if "VAL" in word:
print word
values.append(word.replace("VAL=", ""))
ret = rrd_update('waermepumpe.rrd', 'N:%s:%s:%s:%s:%s:%s:%s:%s:%s:%s' %(values[0], values[1], values[2], values[3], values[4], values[5], values[6], values[7], values[8], values[9]))
HOST = '172.31.24.15'
PORT = 4001
s = None
for res in socket.getaddrinfo(HOST, PORT, socket.AF_INET, socket.SOCK_STREAM):
af, socktype, proto, canonname, sa = res
try:
s = socket.socket(af, socktype, proto)
except socket.error as msg:
s = None
continue
try:
s.connect(sa)
except socket.error as msg:
s.close()
s = None
continue
break
if s is None:
print "Could not open socket"
sys.exit(1)
update_rrd([LIN, RID, TEMP_OUT, TEMP_WATER, TEMP_VORL, TEMP_RUCKL, EQ_ENTRY, EQ_EXIT, TEMP_STEAM, TEMP_COND, HPUMP, PRIO_WATER, LOUT])
#query(LIN)
#query(RID)
#query(HPUMP)
#query(PRIO_WATER)
#query(TEMP_OUT)
#query(TEMP_WATER)
#query(TEMP_VORL)
#query(TEMP_RUCKL)
#query(EQ_ENTRY)
#query(EQ_EXIT)
#query(TEMP_GAS)
#query(COMPR)
#query(TEMP_FWATER)
#query(TEMP_STEAM)
#query(TEMP_COND)
#query(LOW_PRESS)
#query(HIGH_PRESS)
#query(HPUMP)
#query(PRIO_WATER)
#query(FWATER_PUMP)
#query(HSHOULD)
#query(OPMODE)
#query(WNORMAL)
#query(WMIN)
#query(HOURS_COMP_WW)
#query(HOURS_COMP_HEAT)
#query(HOURS_COMP_TOTAL)
#query(LOUT)
s.close()