Protocol frame structure

Request field bytes Details
app_id 12 string
controller id 6 string
encrypted 1 ' '=No, '*'=RSA, '-'=xtea
start 1 STX=2
function 2 ascii function code number
seqnum 2 ascii sequence number
pincode 10 ascii, spaces when unencrypted
timestamp 10 ascii seconds since 01.01.1970
extra 4 future use
payloadsize 3 ascii number
payload n
end 1 EOT=4
Response field bytes Details
app_id 12 string
controller id 6 string
start 1 STX=2
function 2 ascii function code number
seqnum 2 ascii sequence number
response code 1
payloadsize 3 ascii number
payload n
end 1 EOT=4
Function codes Function
0 Discovery
1 Read setup value
2 Set setup value
3 Read setup range
4 Read operating data
5 Read advanced data
6 Read consumption data
7 Read chart data
8 Read event log
9 Read info
10 Read avail. programs

Read setup values

Setup values are read in groups or one by one using function code 1. Set payload to group/* to read all settings in the group. Set payload to group/setting to read one setting.

Available setting groups
boiler
hot_water
regulation
weather
weather2
oxygen
cleaning
hopper
fan
auger
ignition
pump
sun
vacuum
misc
alarm
manual