Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

iCubGenova11 S/N:050 – Right thumb proximal tendon broken #1702

Closed
fedeceola opened this issue Dec 12, 2023 · 9 comments
Closed

iCubGenova11 S/N:050 – Right thumb proximal tendon broken #1702

fedeceola opened this issue Dec 12, 2023 · 9 comments
Assignees
Labels
iCubGenova11 S/N:050 iCub2.7 S/N:050 pinned This label prevents an issue from being closed automatically

Comments

@fedeceola
Copy link

fedeceola commented Dec 12, 2023

Robot Name 🤖

iCubGenova11 S/N:050

Request/Failure description

As per title, while running some experiments the proximal tendon of the right thumb broke.

Detailed context

As per title, while running some experiments the proximal tendon of the right thumb broke. I cannot run my experiments and I have an upcoming deadline for a paper submission.

Additional context

No response

How does it affect you?

I cannot run my experiments and I have an upcoming deadline for a paper submission.

@github-actions github-actions bot changed the title Right thumb proximal tendon broken Robot Name – Right thumb proximal tendon broken Dec 12, 2023
Copy link

⚠️ Detected missing mandatory information

Hi @fedeceola 👋🏻

Some of the following points need your attention.

You are required to:

  • enter the Robot Name, adjust the Issue Title and add the Robot Label.
  • give the issue a meaningful Title.
  • provide a Detailed Context.

Please, mark the points above as solved once done.

@fedeceola fedeceola changed the title Robot Name – Right thumb proximal tendon broken iCubGenova11 S/N:050 – Right thumb proximal tendon broken Dec 12, 2023
@fedeceola fedeceola added the iCubGenova11 S/N:050 iCub2.7 S/N:050 label Dec 12, 2023
@fedeceola
Copy link
Author

Hi, are there any plans to fix this? I'd need to do some tests by the end of the week.

@sgiraz
Copy link
Contributor

sgiraz commented Jan 23, 2024

Hi @fedeceola,

Today @GiacomoVassallo13 started the maintenance activity on iCubGenova11, further updates will follow tomorrow morning

cc @AntonioConsilvio

@fedeceola
Copy link
Author

Hi, with @AntonioAzocar we just tried to run the robot. It cannot complete the calibration of the right thumb. The motor of the proximal joint is moving but the finger doesn't close. Furthermore, the tactile sensor of the thumb is not working.

cc @sgiraz @GiacomoVassallo13 @AntonioConsilvio

@GiacomoVassallo13
Copy link

GiacomoVassallo13 commented Jan 29, 2024

Hi. The rigth prossimal yoint of thumb has been replaced. The yoint was been tested by @fedeceola.
cc: @sgiraz

@fedeceola
Copy link
Author

Hi, actually I couldn't test the joint because, due to the issue in #1723, the right hand couldn't finish the calibration.

@sgiraz sgiraz added the pinned This label prevents an issue from being closed automatically label Feb 28, 2024
@AntonioConsilvio
Copy link
Contributor

Hi @fedeceola! Today I checked the status of the robot.

All tendons were intact, but the right thumb proximal joint didn't work because the connector was quite detached from the MC4-PLUS.

Now all joints are working properly:

VID_20240306_140401.mp4

In addiction I fixed the configuration files, see the PR:

cc @sgiraz

@fedeceola
Copy link
Author

Hi @AntonioConsilvio, thanks! I'll do some tests these days!

cc @lornat75

@fedeceola
Copy link
Author

Hi, yesterday and today I did some tests. The thumb is working. I think that we can close the issue. Thanks!

@sgiraz sgiraz closed this as completed Mar 14, 2024
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
iCubGenova11 S/N:050 iCub2.7 S/N:050 pinned This label prevents an issue from being closed automatically
Projects
Status: Done
Development

No branches or pull requests

4 participants