Find reason for example file failure
Browse files Browse the repository at this point in the history
  • Loading branch information
rraustad committed Feb 8, 2020
1 parent d6972ae commit 35f373a
Show file tree
Hide file tree
Showing 2 changed files with 32 additions and 35 deletions.
65 changes: 31 additions & 34 deletions src/EnergyPlus/HVACVariableRefrigerantFlow.cc
Original file line number Diff line number Diff line change
Expand Up @@ -6246,7 +6246,7 @@ namespace HVACVariableRefrigerantFlow {
// TerminalUnitList(TUListIndex)%HRCoolRequest(IndexToTUInTUList) - TU will operate in this mode if heat recovery is used
// TerminalUnitList(TUListIndex)%HRHeatRequest(IndexToTUInTUList) - TU will operate in this mode if heat recovery is used

getVRFTUZoneLoad(VRFTUNum, QZnReq, LoadToHeatingSP, LoadToCoolingSP);
getVRFTUZoneLoad(VRFTUNum, QZnReq, LoadToHeatingSP, LoadToCoolingSP, false);

if (std::abs(QZnReq) < DataHVACGlobals::SmallLoad) QZnReq = 0.0;
// set initial terminal unit operating mode for heat recovery
Expand Down Expand Up @@ -8129,7 +8129,7 @@ namespace HVACVariableRefrigerantFlow {
this->SuppHeatPartLoadRatio = min(1.0, SuppHeatCoilLoad / this->DesignSuppHeatingCapacity);
}
} else {
getVRFTUZoneLoad(VRFTUNum, ZoneLoad, LoadToHeatingSP, LoadToCoolingSP);
getVRFTUZoneLoad(VRFTUNum, ZoneLoad, LoadToHeatingSP, LoadToCoolingSP, false);
if ((FullOutput < (LoadToHeatingSP - DataHVACGlobals::SmallLoad)) && !FirstHVACIteration) {
SuppHeatCoilLoad = max(0.0, LoadToHeatingSP - FullOutput);
this->SuppHeatingCoilLoad = SuppHeatCoilLoad;
Expand Down Expand Up @@ -9056,7 +9056,7 @@ namespace HVACVariableRefrigerantFlow {
// Constant fan systems are tested for ventilation load to determine if load to be met changes.
// more logic may be needed here, what is the OA flow rate, was last mode heating or cooling, what control is used, etc...

getVRFTUZoneLoad(TUIndex, ZoneLoad, LoadToHeatingSP, LoadToCoolingSP);
getVRFTUZoneLoad(TUIndex, ZoneLoad, LoadToHeatingSP, LoadToCoolingSP, true);

if (VRF(VRFCond).ThermostatPriority == ThermostatOffsetPriority) {
// for TSTATPriority, just check difference between zone temp and thermostat setpoint
Expand Down Expand Up @@ -9575,15 +9575,9 @@ namespace HVACVariableRefrigerantFlow {
}
}

void getVRFTUZoneLoad(int const VRFTUNum, Real64 &zoneLoad, Real64 &LoadToHeatingSP, Real64 &LoadToCoolingSP)
void getVRFTUZoneLoad(int const VRFTUNum, Real64 &zoneLoad, Real64 &LoadToHeatingSP, Real64 &LoadToCoolingSP, bool const InitFlag)
{

//if (!HeatingLoad(VRFTU(VRFTUNum).VRFSysNum) && !CoolingLoad(VRFTU(VRFTUNum).VRFSysNum)) {
// zoneLoad = 0.0;
// LoadToHeatingSP = 0.0;
// LoadToCoolingSP = 0.0;
// return;
//}
if (VRFTU(VRFTUNum).zoneSequenceCoolingNum > 0 && VRFTU(VRFTUNum).zoneSequenceHeatingNum > 0 && VRFTU(VRFTUNum).isInAirLoop) {
// air loop equipment uses sequenced variables
LoadToCoolingSP = DataZoneEnergyDemands::ZoneSysEnergyDemand(VRFTU(VRFTUNum).ZoneNum)
Expand All @@ -9609,11 +9603,22 @@ namespace HVACVariableRefrigerantFlow {
}
} else if (VRFTU(VRFTUNum).ZoneNum > 0) {
// zone equipment uses Remaining* variables
zoneLoad = ZoneSysEnergyDemand(VRFTU(VRFTUNum).ZoneNum).RemainingOutputRequired / VRFTU(VRFTUNum).controlZoneMassFlowFrac;
LoadToCoolingSP = DataZoneEnergyDemands::ZoneSysEnergyDemand(VRFTU(VRFTUNum).ZoneNum).RemainingOutputReqToCoolSP /
VRFTU(VRFTUNum).controlZoneMassFlowFrac;
LoadToHeatingSP = DataZoneEnergyDemands::ZoneSysEnergyDemand(VRFTU(VRFTUNum).ZoneNum).RemainingOutputReqToHeatSP /
VRFTU(VRFTUNum).controlZoneMassFlowFrac;
if (InitFlag) {
// this will need more investigation. Using Remaining* variable during the initial load calculation seems wrong.
// This may also have implications when VRF TUs are in the air loop or if SP control is used
// another question is whether initialization of the opeating mode should look at TotalOutputRequired or RemainingOutputRequired
zoneLoad = ZoneSysEnergyDemand(VRFTU(VRFTUNum).ZoneNum).RemainingOutputRequired / VRFTU(VRFTUNum).controlZoneMassFlowFrac;
LoadToCoolingSP = DataZoneEnergyDemands::ZoneSysEnergyDemand(VRFTU(VRFTUNum).ZoneNum).OutputRequiredToCoolingSP /
VRFTU(VRFTUNum).controlZoneMassFlowFrac;
LoadToHeatingSP = DataZoneEnergyDemands::ZoneSysEnergyDemand(VRFTU(VRFTUNum).ZoneNum).OutputRequiredToHeatingSP /
VRFTU(VRFTUNum).controlZoneMassFlowFrac;
} else {
zoneLoad = ZoneSysEnergyDemand(VRFTU(VRFTUNum).ZoneNum).RemainingOutputRequired / VRFTU(VRFTUNum).controlZoneMassFlowFrac;
LoadToCoolingSP = DataZoneEnergyDemands::ZoneSysEnergyDemand(VRFTU(VRFTUNum).ZoneNum).RemainingOutputReqToCoolSP /
VRFTU(VRFTUNum).controlZoneMassFlowFrac;
LoadToHeatingSP = DataZoneEnergyDemands::ZoneSysEnergyDemand(VRFTU(VRFTUNum).ZoneNum).RemainingOutputReqToHeatSP /
VRFTU(VRFTUNum).controlZoneMassFlowFrac;
}
} else if (VRFTU(VRFTUNum).isSetPointControlled) {
if (VRFTU(VRFTUNum).coolSPActive) {
LoadToCoolingSP = VRFTU(VRFTUNum).coolLoadToSP;
Expand Down Expand Up @@ -10117,22 +10122,14 @@ namespace HVACVariableRefrigerantFlow {
HRCoolRequestFlag = false;
}

// identifies a logic error in finding CoolingLoad = true where TU_CoolingLoad = 0
// logic error needs to be identified and corrected (using VariableRefrigerantFlow_FluidTCtrl_wSuppHeater_5Zone)
// to see logic error resulting in divide by 0, change to this:
// bool coolingLoad = CoolingLoad(VRFCond);
// bool heatingLoad = HeatingLoad(VRFCond);
bool coolingLoad = CoolingLoad(VRFCond) && (TU_CoolingLoad > 0.0);
bool heatingLoad = HeatingLoad(VRFCond) && (TU_HeatingLoad > 0.0);

// Initialization for Ncomp iterations
NumOfCompSpdInput = this->CompressorSpeed.size();
CompEvaporatingPWRSpd.dimension(NumOfCompSpdInput);
CompEvaporatingCAPSpd.dimension(NumOfCompSpdInput);
this->OperatingMode = 0; // report variable for heating or cooling mode

// 1. VRF-HP Cooling Mode .OR. VRF-HR Mode_1
if ((!this->HeatRecoveryUsed && coolingLoad ) || (this->HeatRecoveryUsed && !HRHeatRequestFlag && HRCoolRequestFlag)) {
if ((!this->HeatRecoveryUsed && CoolingLoad(VRFCond) ) || (this->HeatRecoveryUsed && !HRHeatRequestFlag && HRCoolRequestFlag)) {

this->OperatingMode = ModeCoolingOnly;
this->VRFOperationSimPath = 10;
Expand Down Expand Up @@ -10352,7 +10349,7 @@ namespace HVACVariableRefrigerantFlow {
this->IUEvapHeatRate = TU_CoolingLoad;

// 2. VRF-HP Heating Mode .OR. VRF-HR Mode_6
} else if ((!this->HeatRecoveryUsed && heatingLoad ) || (this->HeatRecoveryUsed && !HRCoolRequestFlag && HRHeatRequestFlag)) {
} else if ((!this->HeatRecoveryUsed && HeatingLoad(VRFCond) ) || (this->HeatRecoveryUsed && !HRCoolRequestFlag && HRHeatRequestFlag)) {

this->OperatingMode = ModeHeatingOnly;
this->VRFOperationSimPath = 60;
Expand Down Expand Up @@ -10797,7 +10794,7 @@ namespace HVACVariableRefrigerantFlow {
}

// calculate capacities and energy use
if (((!this->HeatRecoveryUsed && coolingLoad) || (this->HeatRecoveryUsed && HRCoolRequestFlag)) &&
if (((!this->HeatRecoveryUsed && CoolingLoad(VRFCond)) || (this->HeatRecoveryUsed && HRCoolRequestFlag)) &&
TerminalUnitList(TUListNum).CoolingCoilPresent(NumTUInList)) {
InletAirWetBulbC = SumCoolInletWB;

Expand All @@ -10811,7 +10808,7 @@ namespace HVACVariableRefrigerantFlow {
CoolingPLR = 0.0;
}
}
if (((!this->HeatRecoveryUsed && heatingLoad) || (this->HeatRecoveryUsed && HRHeatRequestFlag)) &&
if (((!this->HeatRecoveryUsed && HeatingLoad(VRFCond)) || (this->HeatRecoveryUsed && HRHeatRequestFlag)) &&
TerminalUnitList(TUListNum).HeatingCoilPresent(NumTUInList)) {
InletAirDryBulbC = SumHeatInletDB;
InletAirWetBulbC = SumHeatInletWB;
Expand Down Expand Up @@ -10906,7 +10903,7 @@ namespace HVACVariableRefrigerantFlow {
if (!this->HRCoolingActive && !this->HRHeatingActive) {
this->ModeChange = true;
}
if (coolingLoad) {
if (CoolingLoad(VRFCond)) {
if (this->HRHeatingActive && !this->HRCoolingActive) {
this->HRModeChange = true;
}
Expand All @@ -10919,7 +10916,7 @@ namespace HVACVariableRefrigerantFlow {
HRInitialEIRFrac = this->HRInitialCoolEIRFrac; // Fractional cooling degradation at the start of heat recovery from cooling mode
HREIRTC = this->HRCoolEIRTC; // Time constant used to recover from initial degradation in cooling heat recovery

} else if (heatingLoad) {
} else if (HeatingLoad(VRFCond)) {
if (!this->HRHeatingActive && this->HRCoolingActive) {
this->HRModeChange = true;
}
Expand Down Expand Up @@ -11085,7 +11082,7 @@ namespace HVACVariableRefrigerantFlow {
// if ( this->CondenserType == DataHVACGlobals::EvapCooled )

// Calculate OperatingHeatingCOP & OperatingCoolingCOP: VRF Heat Pump Operating COP []
if (coolingLoad && CoolingPLR > 0.0) {
if (CoolingLoad(VRFCond) && CoolingPLR > 0.0) {
if (this->ElecCoolingPower != 0.0) {
// this calc should use delivered capacity, not condenser capacity, use VRF(VRFCond).TUCoolingLoad
this->OperatingCoolingCOP = (this->TotalCoolingCapacity) /
Expand All @@ -11094,7 +11091,7 @@ namespace HVACVariableRefrigerantFlow {
this->OperatingCoolingCOP = 0.0;
}
}
if (heatingLoad && HeatingPLR > 0.0) {
if (HeatingLoad(VRFCond) && HeatingPLR > 0.0) {
// this calc should use delivered capacity, not condenser capacity, use VRF(VRFCond).TUHeatingLoad
if (this->ElecHeatingPower != 0.0) {
this->OperatingHeatingCOP = (this->TotalHeatingCapacity) /
Expand All @@ -11114,7 +11111,7 @@ namespace HVACVariableRefrigerantFlow {
// limit the TU capacity when the condenser is maxed out on capacity
// I think this next line will make the max cap report variable match the coil objects, will probably change the answer though
// IF(CoolingLoad(VRFCond) .AND. NumTUInCoolingMode .GT. 0 .AND. MaxCoolingCapacity(VRFCond) == MaxCap)THEN
if (coolingLoad && NumTUInCoolingMode > 0) {
if (CoolingLoad(VRFCond) && NumTUInCoolingMode > 0) {

// IF TU capacity is greater than condenser capacity find maximum allowed TU capacity (i.e., conserve energy)
if (TU_CoolingLoad > TotalTUCoolingCapacity) {
Expand All @@ -11127,7 +11124,7 @@ namespace HVACVariableRefrigerantFlow {
TerminalUnitList(TUListNum).TotalHeatLoad,
MaxHeatingCapacity(VRFCond));
}
} else if (heatingLoad && NumTUInHeatingMode > 0) {
} else if (HeatingLoad(VRFCond) && NumTUInHeatingMode > 0) {
// IF TU capacity is greater than condenser capacity
if (TU_HeatingLoad > TotalTUHeatingCapacity) {
LimitTUCapacity(VRFCond,
Expand Down Expand Up @@ -11272,7 +11269,7 @@ namespace HVACVariableRefrigerantFlow {
this->SuppHeatPartLoadRatio = min(1.0, SuppHeatCoilLoad / this->DesignSuppHeatingCapacity);
}
} else {
getVRFTUZoneLoad(VRFTUNum, ZoneLoad, LoadToHeatingSP, LoadToCoolingSP);
getVRFTUZoneLoad(VRFTUNum, ZoneLoad, LoadToHeatingSP, LoadToCoolingSP, false);
if ((FullOutput < (LoadToHeatingSP - DataHVACGlobals::SmallLoad)) && !FirstHVACIteration) {
SuppHeatCoilLoad = max(0.0, LoadToHeatingSP - FullOutput);
this->SuppHeatingCoilLoad = SuppHeatCoilLoad;
Expand Down
2 changes: 1 addition & 1 deletion src/EnergyPlus/HVACVariableRefrigerantFlow.hh
Original file line number Diff line number Diff line change
Expand Up @@ -919,7 +919,7 @@ namespace HVACVariableRefrigerantFlow {

int GetVRFTUReturnAirNode(int const VRFTUNum);

void getVRFTUZoneLoad(int const VRFTUNum, Real64 &zoneLoad, Real64 &LoadToHeatingSP, Real64 &LoadToCoolingSP);
void getVRFTUZoneLoad(int const VRFTUNum, Real64 &zoneLoad, Real64 &LoadToHeatingSP, Real64 &LoadToCoolingSP, bool const InitFlag);

void ReportVRFTerminalUnit(int VRFTUNum); // index to VRF terminal unit

Expand Down

6 comments on commit 35f373a

@nrel-bot-2
Copy link

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

NFP---Connect-split-DX-to-VRF-refrigerant-loop (rraustad) - x86_64-Linux-Ubuntu-18.04-cppcheck: OK (0 of 0 tests passed, 0 test warnings)

Build Badge

@nrel-bot-2
Copy link

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

NFP---Connect-split-DX-to-VRF-refrigerant-loop (rraustad) - x86_64-Linux-Ubuntu-18.04-custom_check: OK (11 of 11 tests passed, 0 test warnings)

Build Badge

@nrel-bot-2c
Copy link

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

NFP---Connect-split-DX-to-VRF-refrigerant-loop (rraustad) - x86_64-Linux-Ubuntu-18.04-gcc-7.4: OK (2668 of 2668 tests passed, 0 test warnings)

Build Badge Test Badge

@nrel-bot-2
Copy link

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

NFP---Connect-split-DX-to-VRF-refrigerant-loop (rraustad) - x86_64-Linux-Ubuntu-18.04-gcc-7.4-UnitTestsCoverage-Debug: OK (1276 of 1276 tests passed, 0 test warnings)

Build Badge Test Badge Coverage Badge

@nrel-bot-2b
Copy link

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

NFP---Connect-split-DX-to-VRF-refrigerant-loop (rraustad) - x86_64-Linux-Ubuntu-18.04-gcc-7.4-IntegrationCoverage-Debug: OK (679 of 680 tests passed, 0 test warnings)

Failures:\n

integration Test Summary

  • Passed: 679
  • Timeout: 1

Build Badge Test Badge Coverage Badge

@nrel-bot
Copy link

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

NFP---Connect-split-DX-to-VRF-refrigerant-loop (rraustad) - Win64-Windows-10-VisualStudio-16: OK (2628 of 2628 tests passed, 0 test warnings)

Build Badge Test Badge