Notifications
You must be signed in to change notification settings - Fork 505
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
Add support for Sanden GAU-A45HPD water heat-pump controller
Issue #1940
- Loading branch information
Showing
3 changed files
with
375 additions
and
0 deletions.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
373 changes: 373 additions & 0 deletions
373
custom_components/tuya_local/devices/sanden_gaua45hpd_heatpumpcontroller.yaml
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,373 @@ | ||
name: Water heater | ||
products: | ||
- id: ssqd7htb3tbhxqvk | ||
name: Sanden GAU-A45HP heat pump controller | ||
primary_entity: | ||
entity: water_heater | ||
dps: | ||
- id: 101 | ||
type: boolean | ||
name: boost_mode | ||
- id: 103 | ||
type: boolean | ||
name: operation_mode | ||
mapping: | ||
- dps_val: false | ||
value: "off" | ||
- constraint: boost_mode | ||
conditions: | ||
- dps_val: true | ||
value: high_demand | ||
- dps_val: false | ||
value: heat_pump | ||
- id: 119 | ||
type: integer | ||
name: current_temperature | ||
unit: C | ||
- id: 139 | ||
type: string | ||
name: tank_model | ||
- id: 140 | ||
type: string | ||
name: heatpump_serial_number | ||
- id: 142 | ||
type: string | ||
name: tank_serial_number | ||
- id: 143 | ||
type: string | ||
name: installation_date | ||
- id: 144 | ||
type: string | ||
name: post_code | ||
- id: 145 | ||
type: string | ||
name: service_date_1 | ||
- id: 146 | ||
type: string | ||
name: service_date_2 | ||
- id: 147 | ||
type: string | ||
name: service_date_3 | ||
- id: 150 | ||
type: string | ||
name: service_error_1 | ||
- id: 151 | ||
type: string | ||
name: service_error_2 | ||
- id: 152 | ||
type: string | ||
name: service_error_3 | ||
secondary_entities: | ||
- entity: switch | ||
name: Air purge | ||
icon: "mdi:pipe-valve" | ||
category: config | ||
dps: | ||
- id: 102 | ||
type: boolean | ||
name: switch | ||
- entity: switch | ||
name: Energy saving | ||
icon: "mdi:leaf" | ||
category: config | ||
dps: | ||
- id: 104 | ||
type: boolean | ||
name: switch | ||
- id: 117 | ||
type: string | ||
name: eco_weight_params | ||
- entity: switch | ||
name: Clock synchronization | ||
icon: "mdi:clock-check" | ||
category: config | ||
dps: | ||
- id: 105 | ||
type: boolean | ||
name: switch | ||
- entity: number | ||
name: Time | ||
category: config | ||
icon: "mdi:clock" | ||
dps: | ||
- id: 106 | ||
type: integer | ||
name: value | ||
unit: min | ||
range: | ||
min: 0 | ||
max: 1439 | ||
- entity: number | ||
name: Block out start | ||
category: config | ||
icon: "mdi:clock-start" | ||
dps: | ||
- id: 107 | ||
type: integer | ||
name: value | ||
unit: h | ||
range: | ||
min: 0 | ||
max: 23 | ||
- entity: number | ||
name: Block out end | ||
category: config | ||
icon: "mdi:clock-end" | ||
dps: | ||
- id: 108 | ||
type: integer | ||
name: value | ||
unit: h | ||
range: | ||
min: 0 | ||
max: 23 | ||
- entity: binary_sensor | ||
class: problem | ||
category: diagnostic | ||
dps: | ||
- id: 109 | ||
type: string | ||
name: sensor | ||
mapping: | ||
- dps_val: "--" | ||
value: false | ||
- value: true | ||
- id: 109 | ||
type: string | ||
name: fault_code | ||
- id: 110 | ||
type: string | ||
name: history_1 | ||
- id: 111 | ||
type: string | ||
name: history_2 | ||
- id: 112 | ||
type: string | ||
name: history_3 | ||
- id: 113 | ||
type: string | ||
name: history_4 | ||
- id: 114 | ||
type: string | ||
name: history_5 | ||
- id: 115 | ||
type: string | ||
name: history_6 | ||
- id: 116 | ||
type: string | ||
name: history_7 | ||
- entity: sensor | ||
name: Status | ||
class: enum | ||
dps: | ||
- id: 118 | ||
type: string | ||
name: sensor | ||
mapping: | ||
- dps_val: "Off" | ||
value: idle | ||
- dps_val: Air_purging | ||
value: air_purging | ||
- dps_val: Freeze_protection | ||
value: anti_freeze | ||
- dps_val: Working | ||
value: heating | ||
- entity: sensor | ||
name: Outlet temperature | ||
class: temperature | ||
category: diagnostic | ||
dps: | ||
- id: 120 | ||
type: integer | ||
name: sensor | ||
unit: C | ||
class: measurement | ||
- entity: sensor | ||
name: Inlet temperature | ||
class: temperature | ||
category: diagnostic | ||
dps: | ||
- id: 121 | ||
type: integer | ||
name: sensor | ||
unit: C | ||
class: measurement | ||
- entity: sensor | ||
name: Discharge temperature | ||
class: temperature | ||
category: diagnostic | ||
dps: | ||
- id: 122 | ||
type: integer | ||
name: sensor | ||
unit: C | ||
class: measurement | ||
- entity: sensor | ||
name: Suction temperature | ||
class: temperature | ||
category: diagnostic | ||
dps: | ||
- id: 123 | ||
type: integer | ||
name: sensor | ||
unit: C | ||
class: measurement | ||
- entity: sensor | ||
name: Evaporator temperature | ||
class: temperature | ||
category: diagnostic | ||
dps: | ||
- id: 124 | ||
type: integer | ||
name: sensor | ||
unit: C | ||
class: measurement | ||
- entity: sensor | ||
class: temperature | ||
category: diagnostic | ||
dps: | ||
- id: 125 | ||
type: integer | ||
name: sensor | ||
unit: C | ||
class: measurement | ||
- entity: sensor | ||
name: Compressor speed | ||
category: diagnostic | ||
dps: | ||
- id: 126 | ||
type: integer | ||
name: sensor | ||
class: measurement | ||
- entity: sensor | ||
name: Water pump speed | ||
category: diagnostic | ||
dps: | ||
- id: 127 | ||
type: integer | ||
name: sensor | ||
class: measurement | ||
- entity: sensor | ||
name: Fan motor speed | ||
category: diagnostic | ||
dps: | ||
- id: 128 | ||
type: integer | ||
name: sensor | ||
class: measurement | ||
- entity: sensor | ||
name: Compressor runtime | ||
class: duration | ||
category: diagnostic | ||
dps: | ||
- id: 129 | ||
type: integer | ||
name: sensor | ||
unit: h | ||
- entity: sensor | ||
name: Compressor runs | ||
category: diagnostic | ||
dps: | ||
- id: 130 | ||
type: integer | ||
name: sensor | ||
unit: times | ||
- entity: sensor | ||
class: current | ||
category: diagnostic | ||
dps: | ||
- id: 131 | ||
type: integer | ||
name: sensor | ||
unit: A | ||
class: measurement | ||
- entity: sensor | ||
name: Heating runtime | ||
class: duration | ||
category: diagnostic | ||
dps: | ||
- id: 132 | ||
type: integer | ||
name: sensor | ||
unit: h | ||
- entity: sensor | ||
name: Defrosting runtime | ||
class: duration | ||
category: diagnostic | ||
dps: | ||
- id: 133 | ||
type: integer | ||
name: sensor | ||
unit: h | ||
- entity: sensor | ||
name: Anti-frost runtime | ||
class: duration | ||
category: diagnostic | ||
dps: | ||
- id: 134 | ||
type: integer | ||
name: sensor | ||
unit: h | ||
- entity: sensor | ||
class: energy | ||
category: diagnostic | ||
dps: | ||
- id: 135 | ||
type: integer | ||
name: sensor | ||
unit: kWh | ||
class: total_increasing | ||
- entity: number | ||
name: Password | ||
category: config | ||
icon: "mdi:dialpad" | ||
dps: | ||
- id: 136 | ||
type: integer | ||
name: value | ||
range: | ||
min: 1000 | ||
max: 6000 | ||
- entity: number | ||
name: Boost time | ||
category: config | ||
icon: "mdi:clock-fast" | ||
dps: | ||
- id: 155 | ||
type: integer | ||
name: value | ||
unit: h | ||
range: | ||
min: 0 | ||
max: 9 | ||
- entity: sensor | ||
name: Estimated hot water | ||
class: volume_storage | ||
category: diagnostic | ||
dps: | ||
- id: 156 | ||
type: integer | ||
name: sensor | ||
unit: L | ||
mapping: | ||
- scale: 10 | ||
- entity: sensor | ||
name: Defrost electric consumption | ||
class: energy | ||
category: diagnostic | ||
dps: | ||
- id: 157 | ||
type: integer | ||
name: sensor | ||
unit: kWh | ||
class: total_increasing | ||
- entity: sensor | ||
name: Anti-frost electric consumption | ||
class: energy | ||
category: diagnostic | ||
dps: | ||
- id: 158 | ||
type: integer | ||
name: sensor | ||
unit: kWh | ||
class: total_increasing |