Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Request support for <KWS-302WF> #2257

Closed
alexps70 opened this issue Aug 30, 2024 · 12 comments
Closed

Request support for <KWS-302WF> #2257

alexps70 opened this issue Aug 30, 2024 · 12 comments

Comments

@alexps70
Copy link

alexps70 commented Aug 30, 2024

Log message

2024-08-30 11:19:11.282 WARNING (MainThread) [custom_components.tuya_local.config_flow] Device matches qoto_03_sprinkler with quality of 28%. DPS: {"updated_at": 1725005939.0350885, "16": true, "101": 2258, "102": 3620, "103": 6284, "104": 8173, "105": 129146, "106": 76, "107": 49, "108": 36, "109": 180, "110": 250, "111": 0, "113": 0, "114": 0, "115": 85, "116": "2", "119": 0, "123": 12495439}

DPS information

{
  "result": {
    "properties": [
      {
        "code": "switch",
        "custom_name": "",
        "dp_id": 16,
        "time": 1724716564621,
        "type": "bool",
        "value": true
      },
      {
        "code": "voltage",
        "custom_name": "",
        "dp_id": 101,
        "time": 1725005091572,
        "type": "value",
        "value": 2267
      },
      {
        "code": "current",
        "custom_name": "",
        "dp_id": 102,
        "time": 1725005091574,
        "type": "value",
        "value": 3977
      },
      {
        "code": "power",
        "custom_name": "",
        "dp_id": 103,
        "time": 1725005091576,
        "type": "value",
        "value": 7427
      },
      {
        "code": "run_time",
        "custom_name": "",
        "dp_id": 104,
        "time": 1725004542821,
        "type": "value",
        "value": 8150
      },
      {
        "code": "energy",
        "custom_name": "",
        "dp_id": 105,
        "time": 1725005090351,
        "type": "value",
        "value": 128975
      },
      {
        "code": "fac",
        "custom_name": "",
        "dp_id": 106,
        "time": 1725005090368,
        "type": "value",
        "value": 82
      },
      {
        "code": "fre",
        "custom_name": "",
        "dp_id": 107,
        "time": 1725005090385,
        "type": "value",
        "value": 50
      },
      {
        "code": "temp",
        "custom_name": "",
        "dp_id": 108,
        "time": 1724998380538,
        "type": "value",
        "value": 37
      },
      {
        "code": "low_voltage",
        "custom_name": "",
        "dp_id": 109,
        "time": 1724716570606,
        "type": "value",
        "value": 180
      },
      {
        "code": "over_voltage",
        "custom_name": "",
        "dp_id": 110,
        "time": 1724716570615,
        "type": "value",
        "value": 250
      },
      {
        "code": "over_current",
        "custom_name": "",
        "dp_id": 111,
        "time": 1724716570629,
        "type": "value",
        "value": 0
      },
      {
        "code": "poweroff_time",
        "custom_name": "",
        "dp_id": 112,
        "time": 1706802634742,
        "type": "value",
        "value": 0
      },
      {
        "code": "over_energy",
        "custom_name": "",
        "dp_id": 113,
        "time": 1724716570635,
        "type": "value",
        "value": 0
      },
      {
        "code": "over_power",
        "custom_name": "",
        "dp_id": 114,
        "time": 1724716570644,
        "type": "value",
        "value": 0
      },
      {
        "code": "over_temp",
        "custom_name": "",
        "dp_id": 115,
        "time": 1724716570663,
        "type": "value",
        "value": 85
      },
      {
        "code": "state_flg",
        "custom_name": "",
        "dp_id": 116,
        "time": 1724716564632,
        "type": "enum",
        "value": "2"
      },
      {
        "code": "flg_save",
        "custom_name": "",
        "dp_id": 117,
        "time": 1706802634742,
        "type": "enum",
        "value": "0"
      },
      {
        "code": "clear_flg",
        "custom_name": "",
        "dp_id": 118,
        "time": 1706802634742,
        "type": "bool",
        "value": false
      },
      {
        "code": "screen_poweroff",
        "custom_name": "",
        "dp_id": 119,
        "time": 1724716570655,
        "type": "value",
        "value": 0
      },
      {
        "code": "jishi_clear",
        "custom_name": "",
        "dp_id": 120,
        "time": 1706802634742,
        "type": "bool",
        "value": false
      },
      {
        "code": "countdown_1",
        "custom_name": "",
        "dp_id": 121,
        "time": 1706802634742,
        "type": "value",
        "value": 0
      },
      {
        "code": "switch_schedule",
        "custom_name": "",
        "dp_id": 122,
        "time": 1706802634742,
        "type": "bool",
        "value": false
      },
      {
        "code": "add_ele",
        "custom_name": "",
        "dp_id": 123,
        "time": 1725005085577,
        "type": "value",
        "value": 12495267
      }
    ]
  },

Product ID

tadm13agjigbdtxd

Product Name

KWS-302WF

Information about how the device functions

No response

@alexps70 alexps70 added the new device Unsupported device label Aug 30, 2024
@make-all
Copy link
Owner

Local log message is required. Not a repeat of the dps info from Tuya cloud.

@make-all make-all closed this as not planned Won't fix, can't repro, duplicate, stale Aug 30, 2024
@make-all make-all removed the new device Unsupported device label Aug 30, 2024
@alexps70
Copy link
Author

2024-08-30 11:19:11.282 WARNING (MainThread) [custom_components.tuya_local.config_flow] Device matches qoto_03_sprinkler with quality of 28%. DPS: {"updated_at": 1725005939.0350885, "16": true, "101": 2258, "102": 3620, "103": 6284, "104": 8173, "105": 129146, "106": 76, "107": 49, "108": 36, "109": 180, "110": 250, "111": 0, "113": 0, "114": 0, "115": 85, "116": "2", "119": 0, "123": 12495439}

@make-all make-all reopened this Aug 30, 2024
@make-all make-all added new device Unsupported device full_info All info needed was provided labels Aug 30, 2024
@make-all
Copy link
Owner

make-all commented Aug 30, 2024

Also, what am I looking at here? What sort of device is a KWS-302WF?

Edit: I see from #2259 that it is an energy meter. I would close this and let that one supercede it, except you reduced the info in dps info, so this one is slightly better. It is still missing info on range and scaling though.

@alexps70
Copy link
Author

Sorry, I thought this request was closed as incorrect, so I created a new one
This is a DIN switch with a display - measures power, power factor, frequency, current, voltage and temperature, counts the consumed energy and time (these counters can be reset). It also has settings for upper and lower voltage protection, overcurrent or power or high temperature.

@alexps70
Copy link
Author

Code Type Values
switch Boolean "{true,false}"
low_voltage Integer { "unit": "V", "min": 100, "max": 220, "scale": 0, "step": 1 }
over_voltage Integer { "unit": "V", "min": 130, "max": 290, "scale": 0, "step": 1 }
over_current Integer { "unit": "A", "min": 0, "max": 100000, "scale": 3, "step": 1 }
poweroff_time Integer { "unit": "min", "min": 0, "max": 60000, "scale": 0, "step": 30 }
over_energy Integer { "unit": "KwH", "min": 0, "max": 99999999, "scale": 3, "step": 1 }
over_power Integer { "unit": "kW", "min": 0, "max": 22000, "scale": 3, "step": 1 }
over_temp Integer { "unit": "°C", "min": -20, "max": 150, "scale": 0, "step": 1 }
flg_save Enum { "range": [ "0", "1", "2" ] }
clear_flg Boolean "{true,false}"
screen_poweroff Integer { "unit": "min", "min": 0, "max": 59, "scale": 0, "step": 1 }
jishi_clear Boolean "{true,false}"
countdown_1 Integer { "unit": "s", "min": 0, "max": 86400, "scale": 0, "step": 1 }
switch_schedule Boolean "{true,false}"

@make-all
Copy link
Owner

Thank you. Closed issues can be reopened if the required info is given. 90% of users never get back with additional info, so I close quickly to avoid having to keep track of too many issues that don't have sufficient info to implement.

@alexps70
Copy link
Author

If any additional information is needed, please advise how to obtain it.

@make-all
Copy link
Owner

What you've provided above should be enough for now.

@SS-IS
Copy link

SS-IS commented Sep 3, 2024

Hello, i have the same energy meter, if you are so kind to help us, that wold be great ! Here's the exact product : https://www.aliexpress.com/item/1005006121485272.html. (KWS-302WF, the second one on the Choose color tab). Thank you !

make-all added a commit that referenced this issue Sep 5, 2024
@make-all make-all added awaiting confirmation Wating for confirmation the issue is solved unreleased Will be in next release and removed full_info All info needed was provided labels Sep 5, 2024
@make-all
Copy link
Owner

make-all commented Sep 5, 2024

An initial implementation has been attempted.
Because the scale info was not available for read-only sensors, some may be scaled incorrectly or have wrong units.
Also, the "flags" feature was not understood, as they are just numeric values which probably have a more meaningful display in the app, so flags were left as attributes of the energy sensor.

@alexps70
Copy link
Author

alexps70 commented Sep 5, 2024

image
how do I check this? I have version 2024.8.0 and when I try to add a new device, unsuitable device options are offered

@make-all make-all removed new device Unsupported device awaiting confirmation Wating for confirmation the issue is solved unreleased Will be in next release labels Sep 8, 2024
@make-all make-all closed this as completed Sep 8, 2024
@alexps70
Copy link
Author

alexps70 commented Sep 9, 2024

Energy (kWh/1000) and power (W/10) readings need to be adjusted
need add "scale" to energy and power
entity: sensor
class: energy
dps:
- id: 105
type: integer
name: sensor
unit: kWh
class: total_increasing
mapping:
- scale: 1000

  • entity: sensor
    class: power
    category: diagnostic
    dps:
    • id: 103
      type: integer
      name: sensor
      unit: W
      class: measurement
      mapping:
      • scale: 10

@make-all make-all added device improvement Improvement to an existing device config awaiting confirmation Wating for confirmation the issue is solved labels Sep 9, 2024
@make-all make-all added the unreleased Will be in next release label Sep 9, 2024
@make-all make-all reopened this Sep 9, 2024
@make-all make-all removed awaiting confirmation Wating for confirmation the issue is solved unreleased Will be in next release device improvement Improvement to an existing device config labels Sep 26, 2024
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
None yet
Projects
Archived in project
Development

No branches or pull requests