Skip to content

Commit

Permalink
Titles
Browse files Browse the repository at this point in the history
  • Loading branch information
ranihorev committed Jul 12, 2019
1 parent 464e02a commit ec3e5e9
Showing 1 changed file with 7 additions and 7 deletions.
14 changes: 7 additions & 7 deletions src/ModbusAnalyzerSettings.cpp
Original file line number Diff line number Diff line change
Expand Up @@ -22,7 +22,7 @@ ModbusAnalyzerSettings::ModbusAnalyzerSettings()


mParityInterface.reset( new AnalyzerSettingInterfaceNumberList() );
mParityInterface->SetTitleAndTooltip( "", "Specify None, Even, or Odd Parity." );
mParityInterface->SetTitleAndTooltip( "Parity Bit", "Specify None, Even, or Odd Parity" );
mParityInterface->AddNumber( ModbusAnalyzerEnums::ParityAndStopbits::EvenOne, "Even Parity Bit (default)", "" );
mParityInterface->AddNumber( ModbusAnalyzerEnums::ParityAndStopbits::OddOne, "Odd Parity Bit", "" );
mParityInterface->AddNumber( ModbusAnalyzerEnums::ParityAndStopbits::NoneTwo, "No Parity Bit, 2 stop bits", "" );
Expand All @@ -38,22 +38,22 @@ ModbusAnalyzerSettings::ModbusAnalyzerSettings()

mModbusModeInterface.reset( new AnalyzerSettingInterfaceNumberList() );
mModbusModeInterface->SetTitleAndTooltip( "Modbus Mode", "Specify which mode of Modbus this is" );
mModbusModeInterface->AddNumber( ModbusAnalyzerEnums::ModbusRTUMaster, "Modbus/RTU - Master", "(messages are transmitted in binary)" );
mModbusModeInterface->AddNumber( ModbusAnalyzerEnums::ModbusRTUSlave, "Modbus/RTU - Slave", "(messages are transmitted in binary)" );
mModbusModeInterface->AddNumber( ModbusAnalyzerEnums::ModbusASCIIMaster, "Modbus/ASCII - Master", "(messages are transmitted in ASCII-readable format)" );
mModbusModeInterface->AddNumber( ModbusAnalyzerEnums::ModbusASCIISlave, "Modbus/ASCII - Slave", "(messages are transmitted in ASCII-readable format)");
mModbusModeInterface->AddNumber( ModbusAnalyzerEnums::ModbusRTUMaster, "RTU - Master", "Messages are transmitted in binary" );
mModbusModeInterface->AddNumber( ModbusAnalyzerEnums::ModbusRTUSlave, "RTU - Slave", "Messages are transmitted in binary" );
mModbusModeInterface->AddNumber( ModbusAnalyzerEnums::ModbusASCIIMaster, "ASCII - Master", "Messages are transmitted in ASCII-readable format" );
mModbusModeInterface->AddNumber( ModbusAnalyzerEnums::ModbusASCIISlave, "ASCII - Slave", "Messages are transmitted in ASCII-readable format");
mModbusModeInterface->SetNumber( mModbusMode );


mBitRateInterface.reset( new AnalyzerSettingInterfaceInteger() );
mBitRateInterface->SetTitleAndTooltip( "Bit Rate (Bits/s)", "Specify the bit rate in bits per second." );
mBitRateInterface->SetTitleAndTooltip( "Bit Rate (Bits/s)", "" );
mBitRateInterface->SetMax( 6000000 );
mBitRateInterface->SetMin( 1 );
mBitRateInterface->SetInteger( mBitRate );


mInvertedInterface.reset( new AnalyzerSettingInterfaceNumberList() );
mInvertedInterface->SetTitleAndTooltip( "", "Specify if the serial signal is inverted" );
mInvertedInterface->SetTitleAndTooltip( "Signal Inversion", "Specify if the serial signal is inverted" );
mInvertedInterface->AddNumber( false, "Non Inverted (Standard)", "" );
mInvertedInterface->AddNumber( true, "Inverted", "" );
mInvertedInterface->SetNumber( mInverted );
Expand Down

0 comments on commit ec3e5e9

Please sign in to comment.