Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

[minigraph] remove number of lanes check for changing speed from 400G to 100G and set speed setting before lane reconfiguration #16452

Merged
merged 2 commits into from
Sep 7, 2023

Conversation

vdahiya12
Copy link
Contributor

@vdahiya12 vdahiya12 commented Sep 5, 2023

… (#15721)
cherry pick conflict #15721
raising a separate PR

8111 800G interface, split to 2x400G (each has 4 lanes) fails to change interface speed from 400G to 100G during deploy mg. In minigraph.xml, the interface speed configuration is good, but fails to generate the right value to config_db.json.

In order to support this SKU the speed transitioning should support both 4 lanes and 8 lanes in the port_config.ini.

Why I did it

before this change for a 400G to 100G transition, in all cases except when lanes are 8, we would continue and the line ports.setdefault(port_name, {})['speed'] = port_speed_png[port_name] would not be executed, hence the default speed will never be set for a case and config_db will not be updated, where speed is transitioning from 400G to 100G or 40G, but lanes are not equal to 8.

In order for those cases to pass where lanes are not specifically 8, we need the change

Work item tracking
24242657

Why I did it

Work item tracking
  • Microsoft ADO (number only):

How I did it

How to verify it

Which release branch to backport (provide reason below if selected)

  • 201811
  • 201911
  • 202006
  • 202012
  • 202106
  • 202111
  • 202205
  • 202211
  • 202305

Tested branch (Please provide the tested image version)

Description for the changelog

Link to config_db schema for YANG module changes

A picture of a cute animal (not mandatory but encouraged)

… to 100G and set speed setting before lane reconfiguration (sonic-net#15721)

8111 800G interface, split to 2x400G (each has 4 lanes) fails to change interface speed from 400G to 100G during deploy mg. In minigraph.xml, the interface speed configuration is good, but fails to generate the right value to config_db.json.

In order to support this SKU the speed transitioning should support both 4 lanes and 8 lanes in the port_config.ini.

Why I did it

before this change for a 400G to 100G transition, in all cases except when lanes are 8, we would continue and the line
ports.setdefault(port_name, {})['speed'] = port_speed_png[port_name]
would not be executed, hence the default speed will never be set for a case and config_db will not be updated,
where speed is transitioning from 400G to 100G or 40G, but lanes are not equal to 8.

In order for those cases to pass where lanes are not specifically 8, we need the change

Work item tracking
24242657

Signed-off-by: vaibhav-dahiya <vdahiya@microsoft.com>
@yxieca
Copy link
Contributor

yxieca commented Sep 6, 2023

@vdahiya12 can you check the build fialures?

Signed-off-by: vaibhav-dahiya <vdahiya@microsoft.com>
@vdahiya12
Copy link
Contributor Author

@vdahiya12 can you check the build fialures?

seems all check passes now @yxieca

@yxieca yxieca merged commit 8f65b78 into sonic-net:202205 Sep 7, 2023
16 checks passed
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment