[Mellanox] support new platform api, thermal and psu part #3175

Merged
merged 3 commits into from
Jul 22, 2019
Merged
Show file tree
Hide file tree
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
27 changes: 18 additions & 9 deletions platform/mellanox/mlnx-platform-api/sonic_platform/chassis.py
Original file line number Diff line number Diff line change
Expand Up @@ -8,19 +8,19 @@
#
#############################################################################

import sys

try:
from sonic_platform_base.chassis_base import ChassisBase
from sonic_platform.psu import Psu
from sonic_platform.fan import Fan
from sonic_platform.fan import FAN_PATH
from sonic_platform.sfp import SFP
from sonic_platform.thermal import Thermal, initialize_thermals
from sonic_platform.watchdog import get_watchdog
from sonic_daemon_base.daemon_base import Logger
from eeprom import Eeprom
from os import listdir
from os.path import isfile, join
import sys
import io
import re
import subprocess
Expand Down Expand Up @@ -64,12 +64,12 @@
COMPONENT_CPLD2 = "CPLD2"

# Global logger class instance
SYSLOG_IDENTIFIER = "mlnx-chassis"
SYSLOG_IDENTIFIER = "mlnx-chassis-api"
logger = Logger(SYSLOG_IDENTIFIER)

# magic code defnition for port number, qsfp port position of each hwsku
# port_position_tuple = (PORT_START, QSFP_PORT_START, PORT_END, PORT_IN_BLOCK, EEPROM_OFFSET)
hwsku_dict = {'ACS-MSN2700': 0, "LS-SN2700":0, 'ACS-MSN2740': 0, 'ACS-MSN2100': 1, 'ACS-MSN2410': 2, 'ACS-MSN2010': 3, 'ACS-MSN3700': 0, 'ACS-MSN3700C': 0, 'Mellanox-SN2700': 0, 'Mellanox-SN2700-D48C8': 0}
hwsku_dict_port = {'ACS-MSN2700': 0, "LS-SN2700":0, 'ACS-MSN2740': 0, 'ACS-MSN2100': 1, 'ACS-MSN2410': 2, 'ACS-MSN2010': 3, 'ACS-MSN3700': 0, 'ACS-MSN3700C': 0, 'Mellanox-SN2700': 0, 'Mellanox-SN2700-D48C8': 0}
port_position_tuple_list = [(0, 0, 31, 32, 1), (0, 0, 15, 16, 1), (0, 48, 55, 56, 1),(0, 18, 21, 22, 1)]

class Chassis(ChassisBase):
Expand All @@ -78,9 +78,12 @@ class Chassis(ChassisBase):
def __init__(self):
super(Chassis, self).__init__()

# Initialize SKU name
self.sku_name = self._get_sku_name()

# Initialize PSU list
for index in range(MLNX_NUM_PSU):
psu = Psu(index)
psu = Psu(index, self.sku_name)
self._psu_list.append(psu)

# Initialize watchdog
Expand Down Expand Up @@ -112,6 +115,9 @@ def __init__(self):
sfp_module = SFP(index, 'SFP')
self._sfp_list.append(sfp_module)

# Initialize thermals
initialize_thermals(self.sku_name, self._thermal_list, self._psu_list)

# Initialize EEPROM
self.eeprom = Eeprom()

Expand All @@ -137,10 +143,13 @@ def _extract_num_of_fans_and_fan_drawers(self):

return num_of_fan, num_of_drawer

def _get_port_position_tuple_by_sku_name(self):
def _get_sku_name(self):
p = subprocess.Popen(GET_HWSKU_CMD, shell=True, stdout=subprocess.PIPE)
out, err = p.communicate()
position_tuple = port_position_tuple_list[hwsku_dict[out.rstrip('\n')]]
return out.rstrip('\n')

def _get_port_position_tuple_by_sku_name(self):
position_tuple = port_position_tuple_list[hwsku_dict_port[self.sku_name]]
return position_tuple

def get_base_mac(self):
Expand Down Expand Up @@ -183,8 +192,8 @@ def _read_generic_file(self, filename, len):
result = fileobj.read(len)
fileobj.close()
return result
except:
logger.log_warning("Fail to read file {}, maybe it doesn't exist".format(filename))
except Exception as e:
logger.log_info("Fail to read file {} due to {}".format(filename, repr(e)))
return ''

def _verify_reboot_cause(self, filename):
Expand Down
148 changes: 123 additions & 25 deletions platform/mellanox/mlnx-platform-api/sonic_platform/psu.py
Original file line number Diff line number Diff line change
Expand Up @@ -8,48 +8,113 @@
#
#############################################################################

import os.path

try:
import os.path
from sonic_platform_base.psu_base import PsuBase
from sonic_daemon_base.daemon_base import Logger
from sonic_platform.fan import Fan
except ImportError as e:
raise ImportError (str(e) + "- required module not found")

# Global logger class instance
SYSLOG_IDENTIFIER = "mlnx-psu-api"
logger = Logger(SYSLOG_IDENTIFIER)

psu_list = []

PSU_CURRENT = "current"
PSU_VOLTAGE = "voltage"
PSU_POWER = "power"

# SKUs with unplugable PSUs:
# 1. don't have psuX_status and should be treated as always present
# 2. don't have voltage, current and power values
hwsku_dict_with_unplugable_psu = ['ACS-MSN2010', 'ACS-MSN2100']

# in most SKUs the file psuX_curr, psuX_volt and psuX_power contain current, voltage and power data respectively.
# but there are exceptions which will be handled by the following dictionary
hwsku_dict_psu = {'ACS-MSN3700': 1, 'ACS-MSN3700C': 1, 'ACS-MSN3800': 1}
psu_profile_list = [
# default filename convention
{
PSU_CURRENT : "power/psu{}_curr",
PSU_VOLTAGE : "power/psu{}_volt",
PSU_POWER : "power/psu{}_power"
},
# for 3700, 3700c, 3800
{
PSU_CURRENT : "power/psu{}_curr",
PSU_VOLTAGE : "power/psu{}_volt_out2",
PSU_POWER : "power/psu{}_power"
}
]

class Psu(PsuBase):
"""Platform-specific Psu class"""
def __init__(self, psu_index):
def __init__(self, psu_index, sku):
global psu_list
PsuBase.__init__(self)
# PSU is 1-based on Mellanox platform
self.index = psu_index + 1
psu_list.append(self.index)
self.psu_path = "/var/run/hw-management/thermal/"
self.psu_oper_status = "psu{}_pwr_status".format(self.index)
self.psu_presence = "psu{}_status".format(self.index)
if os.path.exists(os.path.join(self.psu_path, self.psu_presence)):
self.presence_file_exists = True
self.psu_path = "/var/run/hw-management/"
psu_oper_status = "thermal/psu{}_pwr_status".format(self.index)
#psu_oper_status should always be present for all SKUs
self.psu_oper_status = os.path.join(self.psu_path, psu_oper_status)

if sku in hwsku_dict_psu:
filemap = psu_profile_list[hwsku_dict_psu[sku]]
else:
filemap = psu_profile_list[0]

if sku in hwsku_dict_with_unplugable_psu:
self.always_presence = True
self.psu_voltage = None
self.psu_current = None
self.psu_power = None
self.psu_presence = None
else:
self.presence_file_exists = False
self.always_presence = False
psu_voltage = filemap[PSU_VOLTAGE].format(self.index)
psu_voltage = os.path.join(self.psu_path, psu_voltage)
self.psu_voltage = psu_voltage

psu_current = filemap[PSU_CURRENT].format(self.index)
psu_current = os.path.join(self.psu_path, psu_current)
self.psu_current = psu_current

psu_power = filemap[PSU_POWER].format(self.index)
psu_power = os.path.join(self.psu_path, psu_power)
self.psu_power = psu_power

psu_presence = "thermal/psu{}_status".format(self.index)
psu_presence = os.path.join(self.psu_path, psu_presence)
self.psu_presence = psu_presence

fan = Fan(psu_index, psu_index, True)
if fan.get_presence():
self._fan = fan

def get_status(self):
def _read_generic_file(self, filename, len):
"""
Read a generic file, returns the contents of the file
"""
result = 0
try:
with open(filename, 'r') as fileobj:
result = int(fileobj.read())
except Exception as e:
logger.log_info("Fail to read file {} due to {}".format(filename, repr(e)))
return result

def get_powergood_status(self):
"""
Retrieves the operational status of power supply unit (PSU) defined

Returns:
bool: True if PSU is operating properly, False if not
"""
status = 0
try:
with open(os.path.join(self.psu_path, self.psu_oper_status), 'r') as power_status:
status = int(power_status.read())
except (ValueError, IOError):
status = 0
status = self._read_generic_file(os.path.join(self.psu_path, self.psu_oper_status), 0)

return status == 1

Expand All @@ -60,15 +125,48 @@ def get_presence(self):
Returns:
bool: True if PSU is present, False if not
"""
status = 0
if self.presence_file_exists:
try:
with open(os.path.join(self.psu_path, self.psu_presence), 'r') as presence_status:
status = int(presence_status.read())
except (ValueError, IOError):
status = 0
if self.always_presence:
return self.always_presence
else:
status = self.index in psu_list
status = self._read_generic_file(self.psu_presence, 0)
return status == 1

return status == 1
def get_voltage(self):
"""
Retrieves current PSU voltage output

Returns:
A float number, the output voltage in volts,
e.g. 12.1
"""
if self.psu_voltage is not None and self.get_powergood_status():
voltage = self._read_generic_file(self.psu_voltage, 0)
return float(voltage) / 1000
else:
return None

def get_current(self):
"""
Retrieves present electric current supplied by PSU

Returns:
A float number, the electric current in amperes, e.g 15.4
"""
if self.psu_current is not None and self.get_powergood_status():
amperes = self._read_generic_file(self.psu_current, 0)
return float(amperes) / 1000
else:
return None

def get_power(self):
"""
Retrieves current energy supplied by PSU

Returns:
A float number, the power in watts, e.g. 302.6
"""
if self.psu_power is not None and self.get_powergood_status():
power = self._read_generic_file(self.psu_power, 0)
return float(power) / 1000000
else:
return None
Loading