CLS Silverstone: enable the init sequence for all of the QSFPDD CMIS4… #95

Merged
merged 4 commits into from
Dec 1, 2020
Merged
Show file tree
Hide file tree
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
155 changes: 112 additions & 43 deletions device/celestica/x86_64-cel_silverstone-r0/plugins/sfputil.py
Original file line number Diff line number Diff line change
Expand Up @@ -7,6 +7,7 @@
import syslog
import time
import subprocess
from collections import OrderedDict
from sonic_platform_base.sonic_sfp.sfputilbase import SfpUtilBase
from sonic_platform_base.sonic_sfp.sff8024 import type_of_transceiver
from sonic_platform_base.sonic_sfp.sff8024 import type_of_media_interface
Expand Down Expand Up @@ -265,7 +266,9 @@ def __init__(self):

self.mod_presence = {}
self.mod_failure = {}
self.mod_inited = {}
for x in range(self.PORT_START, self.PORT_END + 1):
self.mod_inited[x] = False
self.mod_failure[x] = 0
self.mod_presence[x] = False

Expand Down Expand Up @@ -409,35 +412,70 @@ def _write_byte(self, port_num, devid, page, off, val):
f.seek(addr)
f.write(chr(val))
except Exception as ex:
log_info("write failed: {0}".format(ex))
log_info("PORT {0}: pg={1}, ofs={2}: write failed: {3}".format(port_num, page, off, ex))
finally:
f.close()

def _init_cmis_module_custom(self, port_num, xcvr, hwsku):
# As of now, init sequence is only necessary for 'INNOLIGHT T-DP4CNT-N00'
if xcvr != 'INNOLIGHT T-DP4CNT-N00':
return True
def _get_application_advertisements(self, eeprom_ifraw=None, offset=85):
adv = OrderedDict()
if eeprom_ifraw is None:
return adv

tbl = self.parse_media_type(eeprom_ifraw, offset)
if tbl is None:
return adv

app = 1
hid = int(eeprom_ifraw[1 + offset], 16)
while (app <= 8) and (hid != 0) and (hid != 0xff):
(ht, mt) = self.parse_application(tbl, eeprom_ifraw[1 + offset], eeprom_ifraw[2 + offset])
adv[app] = "{0} | {1}".format(ht, mt)
app += 1
offset += 4
hid = int(eeprom_ifraw[1 + offset], 16)

return adv

log_info("PORT {0}: {1}: _init_cmis_module_custom".format(port_num, xcvr))
def _get_application_code(self, port_num, host_intf):
Copy link
Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

There is no guarantee that 100G PAM4 mode is always the application 2, and hence we'll need to decode the application advertisement and figure the correct application code

buf = self._read_eeprom_devid(port_num, self.IDENTITY_EEPROM_ADDR, 85, 36)
if buf is None:
return 1

app = 1
dict = self._get_application_advertisements(buf, 0)
for k in dict:
h = dict[k].split('|')[0].strip()
if h in host_intf:
app = k
log_info("PORT {0}: selecting {1}#{2}".format(port_num, app, h))
break
return app

def _init_cmis4_module(self, port_num, xcvr, hwsku):

log_info("PORT {0}: {1}: _init_cmis4_module".format(port_num, xcvr))

# Allow 1s for software reset
self._write_byte(port_num, self.IDENTITY_EEPROM_ADDR, -1, 26, 0x08)
self._write_byte(port_num, self.IDENTITY_EEPROM_ADDR, -1, 26, 0x58)
Copy link
Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Ensure the module will be placed in LowPower mode

time.sleep(1)
# Deinitialize datapath
self._write_byte(port_num, self.IDENTITY_EEPROM_ADDR, 0x10, 128, 0xff)
time.sleep(0.5)
# Hi-Power
self._write_byte(port_num, self.IDENTITY_EEPROM_ADDR, -1, 26, 0x00)
# Application selection
app = 1
if '128x100' in hwsku:
self._write_byte(port_num, self.IDENTITY_EEPROM_ADDR, 0x10, 145, 0x21)
self._write_byte(port_num, self.IDENTITY_EEPROM_ADDR, 0x10, 146, 0x21)
self._write_byte(port_num, self.IDENTITY_EEPROM_ADDR, 0x10, 147, 0x25)
self._write_byte(port_num, self.IDENTITY_EEPROM_ADDR, 0x10, 148, 0x25)
self._write_byte(port_num, self.IDENTITY_EEPROM_ADDR, 0x10, 149, 0x29)
self._write_byte(port_num, self.IDENTITY_EEPROM_ADDR, 0x10, 150, 0x29)
self._write_byte(port_num, self.IDENTITY_EEPROM_ADDR, 0x10, 151, 0x2d)
self._write_byte(port_num, self.IDENTITY_EEPROM_ADDR, 0x10, 152, 0x2d)
app = self._get_application_code(port_num, '100GAUI-2 C2M (Annex 135G),100GBASE-CR2 (Clause 136)')
if app != 1:
self._write_byte(port_num, self.IDENTITY_EEPROM_ADDR, 0x10, 145, (app << 4) | 0x01)
self._write_byte(port_num, self.IDENTITY_EEPROM_ADDR, 0x10, 146, (app << 4) | 0x01)
self._write_byte(port_num, self.IDENTITY_EEPROM_ADDR, 0x10, 147, (app << 4) | 0x05)
self._write_byte(port_num, self.IDENTITY_EEPROM_ADDR, 0x10, 148, (app << 4) | 0x05)
self._write_byte(port_num, self.IDENTITY_EEPROM_ADDR, 0x10, 149, (app << 4) | 0x09)
self._write_byte(port_num, self.IDENTITY_EEPROM_ADDR, 0x10, 150, (app << 4) | 0x09)
self._write_byte(port_num, self.IDENTITY_EEPROM_ADDR, 0x10, 151, (app << 4) | 0x0d)
self._write_byte(port_num, self.IDENTITY_EEPROM_ADDR, 0x10, 152, (app << 4) | 0x0d)
else:
self._write_byte(port_num, self.IDENTITY_EEPROM_ADDR, 0x10, 145, 0x11)
self._write_byte(port_num, self.IDENTITY_EEPROM_ADDR, 0x10, 146, 0x11)
Expand All @@ -450,10 +488,16 @@ def _init_cmis_module_custom(self, port_num, xcvr, hwsku):
self._write_byte(port_num, self.IDENTITY_EEPROM_ADDR, 0x10, 143, 0xff)
# Initialize datapath
self._write_byte(port_num, self.IDENTITY_EEPROM_ADDR, 0x10, 128, 0x00)
time.sleep(0.5)

# Validate configuration status
buf = self._read_eeprom_devid(port_num, self.IDENTITY_EEPROM_ADDR, self._page_to_flat(202, 0x11), 4)
err = "".join(buf)
err = '00000000'
for t in range(10):
Copy link
Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Eoptolink CMIS4 took 6 seconds for config status to get populated to the register, and hence 10 sec should be sufficient

time.sleep(1)
buf = self._read_eeprom_devid(port_num, self.IDENTITY_EEPROM_ADDR, self._page_to_flat(202, 0x11), 4)
err = "".join(buf)
if err == '11111111':
log_info("PORT {0}: it took {1} secs for config ready".format(port_num, t + 1))
break
if err != '11111111':
log_info("PORT {0}: ConfigErr={1}".format(port_num, err))
return False
Expand All @@ -477,7 +521,15 @@ def _init_cmis_module(self, port_num):
#log_info("_init_cmis_module: p={0}, id='{1}', name='{2}', part='{3}'".format(port_num, buf[0], name, part))
xcvr = name.upper() + " " + part.upper()

return self._init_cmis_module_custom(port_num, xcvr, self.hwsku)
# Dispatch as per the CMIS revision id
buf = self._read_eeprom_devid(port_num, self.IDENTITY_EEPROM_ADDR, 0x0, 4)
rev = 0x30
if buf is not None:
rev = int(buf[1], 16)
if rev >= 0x40:
return self._init_cmis4_module(port_num, xcvr, self.hwsku)

Copy link
Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

All of the CMIS3 modules we have are working fine with 4x100G in its default application mode, and hence this init sequence will only be performed on CMIS4 modules.

Note: The definition of the datapath initialiation slightly differs from CMIS3 to CMIS4, and hence we can't use _init_cmis4_module() on CMIS3 modules.

return True

def get_transceiver_change_event(self, timeout=0):
"""
Expand All @@ -501,42 +553,67 @@ def get_transceiver_change_event(self, timeout=0):
flag = self.get_presence(x)
if flag != self.mod_presence[x]:
int_sfp[str(x)] = '1' if flag else '0'
self.mod_inited[x] = False
self.mod_failure[x] = 0
self.mod_presence[x] = flag

# skip the following logic in case of module absent
if not flag:
continue

# Monitoring the QSFP-DD module state, and initiate software reset when failure count > 2
# monitor the QSFP-DD module state, and initiate software reset when failure count > 5
buf = self._read_eeprom_devid(x, self.IDENTITY_EEPROM_ADDR, 0x0, 4)
if buf is None:
log_info("PORT {0}: unable to get module state".format(x))
continue
# skip, in case of QSFP28
if buf[0] not in "18,19":
continue
# skip, in case that CMIS < 3.0
if int(buf[1], 16) < 0x30:
# skip, in case that CMIS < v3.0
cmis = int(buf[1], 16)
if cmis < 0x30:
continue
# advance the failure counter if state != ModuleReady
if ((int(buf[3], 16) >> 1) & 0x7) != 3:
self.mod_failure[x] += 1
# initiate QSFP-DD software reset if failure counter > 2
if self.mod_failure[x] > 2:
# skip the init sequence for CMIS3
if cmis < 0x40:
self.mod_inited[x] = True
# advance the failure counter if state == ModuleLowPwr and CMIS < v4.0
if (cmis < 0x40) and (((int(buf[3], 16) >> 1) & 0x7) == 1):
# fetch the module media type
buf = self._read_eeprom_devid(x, self.IDENTITY_EEPROM_ADDR, 85, 1)
if buf is None:
log_info("PORT {0}: unable to get module media type".format(x))
# perform a software reset only if it's not a DAC (Passive Copper)
elif int(buf[0], 16) != 0x03:
self.mod_failure[x] += 1
else:
self.mod_failure[x] = 0
# initiate QSFP-DD software reset if failure count > 5
if self.mod_failure[x] > 5:
self.mod_failure[x] = 0
# This is actually a hotfix for 'Eoptolink EOLD-134HG-02-M6, QSFPDD CMIS v3',
# its module state could get stuck at ModuleLowPwr upon reinsertion, and a software
# reset is necessary to get it recovered.
log_info("PORT {0}: issuing a software reset".format(x))
self._write_byte(x, self.IDENTITY_EEPROM_ADDR, -1, 26, 0x08)
time.sleep(1)

# Monitoring the QSFP-DD initialization state, and reinitiate it if necessary
# monitor the QSFP-DD initialization state, and reinitiate it if necessary
if self.mod_inited[x]:
continue
buf = self._read_eeprom_devid(x, self.IDENTITY_EEPROM_ADDR, self._page_to_flat(202, 0x11), 4)
if buf is None:
continue
err = "".join(buf)
if err != '11111111':
Copy link
Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Just for a record, this checker is necessary to prevent redundant CMIS4 init upon warm-reboot, otherwise significant packet drops will be observed.

if not self._init_cmis_module(x):
log_info("PORT {0}: Unable to initialize the module".format(x))
else:
self.mod_inited[x] = True

# break if the SFP change event is not empty
if len(int_sfp) > 0:
break

time.sleep(1)
return True, int_sfp

Expand Down Expand Up @@ -594,27 +671,19 @@ def get_eeprom_dict(self, port_num):
return self.get_qsfp_data(eeprom_ifraw)

# decode application advertisement
offset = 85
tbl = self.parse_media_type(eeprom_ifraw, offset)
ret = ""
if tbl is not None:
app = 1
hid = int(eeprom_ifraw[1 + offset], 16)
while (app <= 8) and (hid != 0) and (hid != 0xff):
(ht, mt) = self.parse_application(tbl, eeprom_ifraw[1 + offset], eeprom_ifraw[2 + offset])
ret += "\n {0}: {1} | {2}".format(app, ht, mt)
app += 1
offset += 4
hid = int(eeprom_ifraw[1 + offset], 16)
if len(ret) > 0:
sfp_data['interface']['data']['Application Advertisement'] = ret
apps = ""
dict = self._get_application_advertisements(eeprom_ifraw, 85)
for a in dict:
apps += "\n {0}: {1}".format(a, dict[a])
if len(apps) > 0:
sfp_data['interface']['data']['Application Advertisement'] = apps

# decode the running application code
sel = 1
eeprom_data = self._read_eeprom_devid(port_num, self.IDENTITY_EEPROM_ADDR, 0x880, 32)
if eeprom_data is not None:
sel = int(eeprom_data[145 - 128], 16) >> 4
if sel < 1 or sel >= app:
if sel < 1 or sel > len(dict):
sel = 1
sfp_data['interface']['data']['Application Selected'] = "{0}".format(sel)

Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -2297,4 +2297,4 @@ module_exit(silverstone_exit);
MODULE_AUTHOR("Celestica Inc.");
MODULE_DESCRIPTION("Celestica Silverstone platform driver");
MODULE_VERSION(MOD_VERSION);
MODULE_LICENSE("GPL");
MODULE_LICENSE("GPL");